Speed Queen ADE41F Installation Instructions Manual Download Page 5

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

5

512100

Installing the Dryer

Step 1: Position and Level the Dryer

Install dryer before washer. This allows room for 
attaching exhaust duct.

Select a location with a solid floor. Dryers installed in 
residential garages must be elevated 18 inches (46 cm) 
above the floor.

No other fuel burning appliance should be installed in 
the same closet with the dryer.

The dryer must not be installed or stored in an area 
where it will be exposed to water and/or weather.

The dryers needs sufficient clearance and an adequate 
air supply for proper operation and ventilation, and for 
easier installation and servicing. (Minimum clearances 
are shown below).

Figure 2 

DRY1968N

1

Closet Door

2

Centered Air Openings (2 Openings minimum)

3

Outer Wall of Enclosure

**NOTE: For new installations, locate top of wall vent 42 inches (106.7 cm) above floor to make venting 
easier to connect.

**42 in.

(106.7 cm)

FRONT VIEW

(w/o Closet Door)

SIDE VIEW

FRONT VIEW

(Closet Door)

B

A

A

C

A

D

F

F

E

1

2 (G)

3

Area

Description

Free Standing/Alcove 

Installation

Closet Installation

A

Dryer sides and rear clearance

0 in. (0 cm)

0 in. (0 cm)

B

Dryer top clearance

12 in. (30.5 cm)

12 in. (30.5 cm)

C

Dryer front clearance

Not Applicable

2 in. (5.1 cm)

D

Exhaust duct clearance to 
combustible material

2 in. (5.1 cm)

2 in. (5.1 cm)

E

Weather hood to ground clearance

12 in. (30.5 cm)

12 in. (30.5 cm)

F

Distance from floor or ceiling to 
hole edge

Not Applicable

3 in. (7.6 cm)

G*

Area of centered air openings in 
closet door

Not Applicable

40 sq. in./open (260 sq. cm)

*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)

Summary of Contents for ADE41F

Page 1: ...chine www speedqueen com Installation Instructions for Front Control Dryers Dimensions 3 Before You Start 4 Installing the Dryer 5 Installer Checklist Back Cover Date Purchased _____________________ M...

Page 2: ...qualified installer service agency or the gas supplier W052 FOR YOUR SAFETY the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage pers...

Page 3: ...6 cm 4 0 in 10 2 cm 26 9 in 68 3 cm ELECTRIC DRYERS 8 0 in 20 3 cm 15 4 in 39 1 cm 15 44 in 39 2 cm 37 44 in 95 1 cm DRY2344N With leveling legs turned into base 1 3 8 in NPT Gas Connection DRY2344N...

Page 4: ...ctions User s Guide Product Registration Card Dryer Rack Reply Card Warranty Bond Three screws electric dryers only Refer to Connecting Power Cord sections in Step 4 of Installation DRY2023N 1 Safety...

Page 5: ...68N 1 Closet Door 2 Centered Air Openings 2 Openings minimum 3 Outer Wall of Enclosure NOTE For new installations locate top of wall vent 42 inches 106 7 cm above floor to make venting easier to conne...

Page 6: ...op rivets on all duct joints DO NOT use sheet metal screws or fasteners on exhaust pipe joints which extend into the duct and catch lint DRY2345N 1 Dryer Base 2 Level 3 Leveling Leg 1 2 3 To reduce th...

Page 7: ...ergy efficient homes with low air infiltration rates should be equipped with an air exchanger that can accommodate on demand make up air needs in the home These devices can be obtained through your bu...

Page 8: ...be necessary for installations where heavy snowfall can occur Table 1 NOTE The maximum length of a 4 in 10 2 cm diameter flexible metal duct must not exceed 7 87 ft 2 4 m as required to meet UL2158 cl...

Page 9: ...installed as shown for checking inlet pressure Refer to Figure 5 To reduce the risk of gas leaks fire or explosion The dryer must be connected to the type of gas as shown on nameplate located in the d...

Page 10: ...iagram is located behind the control panel inside the control cabinet Grounding Information This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of e...

Page 11: ...Do not connect dryer to 110 115 or 120 Volt circuit Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that list...

Page 12: ...30 Ampere Fuses or Circuit Breaker 6 Neutral 3 Neutral Wire 7 Terminal Block in Dryer NOTE The power cord is NOT supplied with the electric dryer Type of power cord and gauge of wire must conform to l...

Page 13: ...t Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover and screw Connecting Power Cord with Fou...

Page 14: ...the white wire loop the free eyelet end of the ground wire removed in Step 3 and attach along with the white wire to the neutral center terminal on the terminal block 7 Tighten all screws firmly IMPOR...

Page 15: ...en pull down removing door liner from door panel 4 Rotate door panel 180 degrees as shown 5 Remove door strike from door liner and reinstall on opposite side 6 Insert liner under flange on bottom of d...

Page 16: ...operate both a washer and gas dryer on the same circuit Use separately fused 15 amp circuits The dryer is designed to be operated on a separate branch polarized three wire effectively grounded 120 Vol...

Page 17: ...efer to Installer Checklist on the back cover of this manual and make sure that dryer is installed correctly Step 9 Check Heat Source Electric Dryers Close the loading door and start the dryer in a he...

Page 18: ...Adjust the air shutter to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roaring very blue flame indicates too much air Adjust the air shutter as follows 1...

Page 19: ......

Page 20: ...EVEL D255I D255I 2 DRY688N DRY688N Connect Dryer Exhaust System CHECK 3 GAS ONLY D258I CHECK Connect Gas Supply Pipe Check for Gas Leaks 4 D699I W315IE0A ELECTRIC ONLY Connect Electrical Cord CHECK Re...

Reviews: