13
12
Spectrum
Spectrum
14.
Once the values have been selected move to the next time slot by pressing the next ( ) button
Parameter
Option
Description
Volume of treated water
IF xx.x
Volume of water to be treated
IF-oF
Capacity / Hardness Mode
Parameter
Option
Description
Length of 1
st
cycle
1-xx
Length of cycle in minutes
Length of 2
nd
cycle
2-xx
Length of cycle in minutes
Length of 3
rd
cycle
3-xx
Length of cycle in minutes
Length of 4
th
cycle
4-xx
Length of cycle in minutes
This is the number of minutes per cycle of the regeneration process. The value in minutes can be found in the
‘Cycle
Time Table’
overleaf.
Parameter
Option
Description
1
st
regeneration time slot
xx:H1
Regeneration time
oF:H1
Regeneration time slot disabled
2
nd
regeneration time slot
xx:H2
Regeneration time
oF:H2
Regeneration time slot disabled
3
rd
regeneration time slot
xx:H3
Regeneration time
oF:H3
Regeneration time slot disabled
4
th
regeneration time slot
xx:H4
Regeneration time
oF:H4
Regeneration time slot disabled
8. Valve Programming Set-Up
This is the volume in cubic meters your system can soften. The capacity can be determined with the
‘Capacity
Calculation Table’
overleaf.
9.
Select the appropriate option press the next ( ) button
8.
Adjust the value using the up ( ) and down ( ) arrows.
10.
Adjust the values using the up ( ) and down ( ) arrows.
11.
Once the values have been selected move to the next cycle by pressing the next ( ) button
12.
You can choose up to 4 regeneration slots in
R-3
(delayed mode), allowing you to minimise the risk of hard
water after expiring capacity.
13.
Adjust the values using the up ( ) and down ( ) arrows.
SOME ITEMS MAY NOT BE SHOWN DEPENDING ON VALVE
CONFIGURATION. THE VALVE WILL DISCARD ANY CHANGES
AND EXIT MASTER PROGRAMMING MODE IF ANY BUTTON IS
NOT PRESSED FOR SIXTY SECONDS.
NOTES
8.3. Cycle Time Table
8. Valve Programming Set-Up
Hardness Level
(ppm CaCO
3
)
SWS-5.0M
SWS-12.5M
100
50.0
125.0
120
41.7
104.2
140
35.7
89.3
160
31.3
78.1
180
27.8
69.4
200
25.0
62.5
220
22.7
56.8
240
20.8
52.1
260
19.2
48.1
280
17.9
44.6
300
16.7
41.7
320
15.6
39.1
340
14.7
36.8
360
13.9
34.7
380
13.2
32.9
400
12.5
31.3
420
11.9
29.8
440
11.4
28.4
460
10.9
27.2
480
10.4
26.0
500
10.0
25.0
The values in the table below show the volume of soft water produced between regenerations (m³).
The values in the table below show the length of time in minutes per cycle.
SWS Programming Chart
Parameter
Softener
Capacity
C
Backwash
BW
Brine draw
BD
Rapid rinse
RR
Brine refill
BR
Total
PWS-5.0M
5,000,000
10
70
10
10
100
PWS-12.5M
12,500,000
15
90
15
14
134
8.2. Capacity Calculation Table