background image

5

4

Spectrum

Spectrum

Regeneration Mode

Regeneration Type

Installation Number

Nominal Capacity

m

3

Valve Serial Number

Inlet Water Hardness

ppm/mg/l

Tank Size

Treated Water Volume

litres

Resin Type

Outlet Water Hardness

ppm/mg/l

Resin Volume

litres

Salt Quantity per Regeneration

kg

Volumetric

m

3

Down Flow Brining

1) Brining & Rinse

min

2) Backwash

min

3) Rapid Rinse

min

4) Brine Tank Refill

min

Low Voltage DC Transformer

3. Description & 

     Equipment Adjustments

Please use this sheet to keep a record of your system parameters and installation.

Electrical Supply

4. Components, Features

     & Functions

Component

Features

Functions

SPECTRUM 

7 softening 

control valve

•   FDA compliant GRP valve

•   Strong corrosion resistance

•   Innovative design

•   CE marked

•  24 hours control and monitoring with a timer and meter; 

automatically regenerates the media bed once the 

capacity of a pressure vessel expires

•  Cycle Process:

•  In service: Once the water is supplied with correct 

pressure  and  flow,  the  cations  contained  in  hard 

water will be replaced by Na

+

 in regenerants, then the 

softening system will supply softened water through its 

outlet

•  Backwash: When the ion exchange resin has been  

exhausted,  the  resin  bed  needs  to  be  regenerated. 

Before the regeneration of the resin bed, a backwash 

step is  necessary for two main purposes; removing the 

residue in the resin bed and loosening the impacted 

resin bed for better regeneration efficiency

•  Rinse: Rinse the resin bed to remove the residual 

regenerant (salt) after the brining step until the water 

from outlet contains no regenerant; rinse could also 

compact  the  resin  bed  for  a  better  softening  effect.

Refill: Refill the brine tank with water to dissolve salt for 

the next regeneration

Valve Operation Mode

Softener: Standard water softener operation

Regeneration Mode

Volumetric immediate or delayed with electronic timer

Water Hardness can be adjusted

User can adjust the mixing valve to get desired outlet water 

hardness

Display Format

Metric

Media

NSF 61 and FDA compliant SPECTRUM resin Food grade SPECTRUM softening resin

Pressure 

Vessel

•  NSF 44 tested and certified

•  Polyethylene material manufactured for the 

Food & Beverage industries

•  Light, high pressure resistance

•  Strong corrosion resistance

•  Polyethylene liner with reinforced fibreglass

•  PED compliant

Pressure vessel holds the resin and a distribution system

Riser Tube & 

Distribution 

System

A riser tube and distribution system disperse water evenly 

through the resin bed

Brine Valve 

& Tank

•  High pressure resistance

•  Prevents the brine tank from overflowing

•  Water  and  salt  mix  in  the  brine  tank.  Salt  will  dissolve 

continuously until the water is saturated by salts

Summary of Contents for SWS Simplex

Page 1: ...s Functions p 5 5 Component Contents p 6 6 Valve User Interface p 8 7 Installation Instructions p 9 8 Valve Programming Set up p 11 9 Valve Operation p 14 10 Troubleshooting p 15 11 Cautions p 17 12 Technical Information p 18 Installation Service Operation Manual SWS Simplex Water Softener Spectrum Table of Contents ...

Page 2: ...e water supply line to the softener This unit must be operated at temperatures between 3 C 38 C 37 F and 100 F Do not use this water softener on hot water supplies Do not install this unit where it may be exposed to wet weather direct sunlight or temperatures outside of the range specified above The appliance is only to be used with the power supply unit provided with the appliance Apply provided ...

Page 3: ...eneration of the resin bed a backwash step is necessary for two main purposes removing the residue in the resin bed and loosening the impacted resin bed for better regeneration efficiency Rinse Rinse the resin bed to remove the residual regenerant salt after the brining step until the water from outlet contains no regenerant rinse could also compact the resin bed for a better softening effect Refi...

Page 4: ...iately If you are planning to store the components before installation they should be secured in a dry area with no risk of freezing as it could affect sensitive components such as plastics becoming brittle or electronics potentially failing 5 3 SPECTRUM Brine Tank 5 4 SPECTRUM Softening Resin Volume varies according to the model Dimension varies according to model also includes brine tube and saf...

Page 5: ... is defined as the drainline Water volume and flow estimations are made in the technical data chart at the end of the document The diameter of the flexible drain pipe should be able to accommodate the flow of water to the drain If the water does not flow to the drain properly this will affect the performance of your softener The drain should never be higher than the valve height as the back pressu...

Page 6: ...ming Set Up Parameter Option Description Mode of Regeneration R 1 Chronometric R 2 Volumetric immediate R 3 Volumetric delayed R 4 Adaptive brining R 5 Filter Chronometric R 6 Filter Volumetric immediate R 7 Filter Volumetric delayed Parameter Option Description Brine Flow Direction t df Down flow regeneration t uf Up flow regeneration For your softener please choose the t df setting Parameter Opt...

Page 7: ...appropriate option press the next button 8 Adjust the value using the up and down arrows 10 Adjust the values using the up and down arrows 11 Once the values have been selected move to the next cycle by pressing the next button 12 You can choose up to 4 regeneration slots in R 3 delayed mode allowing you to minimise the risk of hard water after expiring capacity 13 Adjust the values using the up a...

Page 8: ...els The remaining volume of water to be treated can be displayed by pushing the NEXT button 10 1 SWS Simplex Problem Possible Cause Possible Solution A Controller does not work 1 Power off 2 Transformer is not plugged in 3 Defective power cord 4 Defective transformer 1 Switch on power 2 Connect to constant power source 3 Replace cord 4 Replace the transformer B Incorrect time of regeneration 1 Pow...

Page 9: ...control valve without reading and understanding the contents of this manual 2 Ensure the system does not lean during shipping installation and use as this is may cause damage 3 During regeneration the water from the tap will NOT be softened It is NOT recommended to use the water during regeneration as this may have a negative effect on the cycle 4 Initiate a regeneration cycle when the softener ha...

Page 10: ... 7 7 Optimal Flow Rate m3 hr 4 7 Inlet Outlet 1 BSP 1 BSP Valve 716 721 Drain hose fit BSP Brine Line push fit push fit Power Requirements V 240 240 Resin Volume l 100 250 Salt Consumption Per Regeneration kg 12 30 Pressure Tank Thread 2 4 Vessel Size 14x65 21x62 Brine Tank Volume l 140 500 Brine Tank Dimensions mm 582 x 362 x 904 ø 390 x 810 Total Height mm 1955 2032 Total Weight kg 127 316 Regen...

Page 11: ...WWW SPECTRUM FILTRATION COM Spectrum ...