0190236 Page 6 of 10
Control button
Reset Procedure:
1. Unplug, then re-plug the power cord into a wall outlet.
2. Make sure all lift mechanism wire connections are in place and secure.
3. Remove anything located under the worksurface.
4. Press and hold the “Down” button to lower the worksurface to the
lowest “work” position until it stops moving.
5. Release the “Down” button.
6. Press and hold the “Down” button again until the worksurface
bottoms-out, slightly rises, and stops moving. The worksurface must
be completely lowered before resuming operation.
Note: If the worksurface does not lower when doing this step,
release the “Down” button, and retry step 6.
7. Release the “Down” button. The lift mechanism has now been
reset and the worksurface can be adjusted normally.
Down
CAUTION
Always unplug the eLift before working under the worksurface.
Although this table utilizes an anti-collision feature that briefly stops
and reverses the motion of the table in the event of an obstruction,
Use
caution when raising or lowering the worksurface
!
Do not
sit at,
under, or on the worksurface when operating the lift mechanism and be
sure table movement does not interfere with objects or people.
Up
CAUTION
Keep clear of pinch points during worksurface movement.
Note: The lift actuators are rated at a maximum capacity of 180 lb each.
CAUTION
USE CAUTION WHEN RAISING OR LOWERING TABLE!
Curved or rectangular
end worksurface
Control
button
Phillips
screwdriver
Tools
Required
Operation:
1. Plug the 11-foot, 15-amp power cord into a wall outlet.
2. Locate the “Up” and “Down” buttons on the control pad.
3. To raise or lower the worksurface, press and hold the “up” or “down”
arrow keys on the control pad until the worksurface reaches the desired
height. The worksurface maximum height is 42”, minimum height is 29”.
Keep clear of pinch points during worksurface movement.
#8 x 5/8” PHSM
Pine tree clip
Pine tree clip
Figure 7.2
Note: Additional sets of pre-
drilled mounting holes are avail-
able under the straight sections
of the worksurface to mount the
control button if preferred.
Cord
Figure 7.1
eLift operating instructions -
eLift equipped tables only
1. Attach the control button bracket under the radiused portion of the
worksurface with (2) #8 x 5/8” PHSM screws and pre-drilled pilot holes
in the center of the worksurface.
2. Push the control button onto the bracket.
3. Use the included pine tree clips to secure the cord to the worksurface.
To control box
in AV channel