4.  Secure cord reel

5.  Route power cord

0115955R1 Page 3 of 4

connector pin

Figure 4

Figure 5

Tools

 

Required

pliers

1.  With the connector pin installed securing the reel, use pliers to 

bend the straight end of the connector pin to an approximate 45° 

angle.  

Figure 4

.

1.  Route the power cord through the side panel grommet.  

Figure 5

.

Cord reel operation

Operating Instructions:

1.  To latch cord - Pull cord out to full length.  Allow the cord to retract 1-2 feet back into 

the reel.  Pull the cord out slowly.  When a ‘click’ is heard, the cord will latch in place.

2.  Plug into 110-125V (single phase), 3-conductor wall outlet.

3.  To release cord - Unplug from wall outlet.  Pull cord out slowly until clicking stops.  

The latch will release and the cord can be guided back into the reel.  Do not allow the 

cord to fly unrestricted back into the reel.

4.  Do not overload or circuit breaker (15-amp maximum) will cut off current.  To restore 

power, remove overload, wait two minutes, then reset the circuit breaker by pressing 

the button on the back of the 3-prong male power plug.

Maintenance:

1.  Unplug cord reel before performing maintenance.

2.  Remove dirt and grime as soon as it accumulates on the reel case by using a soft, 

damp cloth (a mild detergent may be used if needed), being careful not to wet 

the electrical plug.  Never immerse any part of the unit in any solution to clean.          

DO NOT

 use solvents such as gasoline, turpentine, etc. to clean unit.

3.  Keep cord clean to assure smoothest automatic retraction.  Simply pull cord to its 

full length and allow to retract through a dampened rag.  Pull out full length again 

and sprinkle cord with talcum powder.

Specifications:

1875W, 15A, 125V, 15’ retractable, 12 AWG with breaker, UL Listed

WARNING

•  This cord reel is intended for general indoor use only.  It is not intended to be used 

in potentially dangerous locations such as flammable or explosive atmospheres.

•  The cord reel is not waterproof and not intended for use in potentially wet locations.

•  Do not overload (15-amp maximum).

reset button

power plug

Summary of Contents for 99037

Page 1: ...uired Vertical left power cord takes up 6RU Vertical right power cord takes up 6RU Horizontal right power cord takes up 3RU Note The cord reel takes up rack unit height and depth in all 3 positions If you plan to install rack mount equipment at or near the base panel be aware of the height and depth available for the components before installing the cord reel Setting the cord reel onto the base pa...

Page 2: ...re 3C Figure 3A left side of typical base panel right side of typical base panel mounting bracket mounting bracket mounting bracket cord reel cord reel cord reel connector pin connector pin connector pin 14 x 7 8 PHSM screw 3 required 14 x 7 8 PHSM screw 3 required 14 x 7 8 PHSM screw 3 required right side of typical base panel left side of typical base panel right side of typical base panel right...

Page 3: ...ore power remove overload wait two minutes then reset the circuit breaker by pressing the button on the back of the 3 prong male power plug Maintenance 1 Unplug cord reel before performing maintenance 2 Remove dirt and grime as soon as it accumulates on the reel case by using a soft damp cloth a mild detergent may be used if needed being careful not to wet the electrical plug Never immerse any par...

Page 4: ...SPECTRUM SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES WHETHER ARISING OUT OF BREACH OF CONTRACT WARRANTY TORT INCLUDING NEGLIGENCE AND STRICT LIABIL ITY OR OTHER THEORIES OF LAW WITH RESPECT TO PRODUCTS SOLD OR SERVICES RENDERED BY SPECTRUM OR ANY UNDERTAK INGS ACTS OR OMISSIONS RELATING THERETO Our Customer Service Department is ready to provide immediate attention to any question...

Reviews: