1-6
Chapter 1, Module Overview
User’s Manual Pub. 0300322-01 Rev. B
Input Specifications
Value
Power Requirements
Bus +5 V (4.75 V to 5.4 V)
100 mA maximum
Bus +24 V (19.9 V to
26.4 V)
20 mA maximum
Power Dissipation within
module
1 W max
Inrush current
Less than 150 mA at 5 V; less than 400 mA at 24 V
Fusing
UL approved and properly sized SMD fuse or properly sized
fuse resistors on both the 24 VDC and 5 VDC power supply
lines.
Fault detection
Over/under range for all types
Open Circuit detection
Note: Thermocouple open circuit (open wire) will be
periodically checked using the PGA burnout current. This
saves on component cost and increases the Voltage Input
impedance.
Wire Installation
Wire size
#16 to #28 AWG
Wire Strip Length
0.375 in.
Recommended Tightening
Torque:
0.25 N-m (2.2 in-lbs.)
Module Dimensions
110 mm × 87 mm × 51 mm (plastic only).
(4.33 in × 3.43 in × 2.00 in)
110 mm × 89 mm × 51 mm (with RTBs installed).
(4.33 in × 3.5 in × 2.00 in)
(CJC adds additional height beyond this)
Table 1-2. Environmental Specification Table
Environmental Tests
Test Limits
Temperature (Operating)
(Performance Criteria A)
-20 ºC to 65 ºC (-4 ºF to 149 ºF)
Temperature
(Non-operating)
(Performance Criteria B)
-40 ºC to 85 ºC (-40 ºF to 185 ºF)
Humidity (Operating)
(Performance Criteria A)
5 to 95% non-condensing
Vibration (Operating)
(Performance Criteria A)
2 G at 10 to 500 Hz, 0.030 in. max. peak-to-peak