SpectraPure
SpectraPure®Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
®
6
Sediment Pre-Filter
1 micron MicroTec™ sediment pre-filter
Carbon Filter
1 micron carbon block pre-filter
RO Membrane Type
Thin-Film Composite (TFC)
Rejection
Rate 98%
average
Input Water Pressure
60 psi (4.15 bar) line pressure*
Input Water Temp
77°F (25°C)
Recovery Rate
25% (i.e. 25% of the water will be
collected
as
pure
water)
Nominal Membrane Flow Rates @ 60 psi, 77° F, & 500 ppm TDS :
GPD
Product Water Flow Rate
Concentrate Flow Rate
100
263 ml/min
789 ml/min
200
526
ml/min
1578
ml/min
Reverse Osmosis Feed Water Requirements
For the 1 year TFC membrane pro-rated warranty to be honored, the following conditions
must be met:
Operating Pressure*
40 – 80 psi (2.75 – 5.5 bar)
pH
Range 3
–
11
Maximum Temperature
100° F (38° C)
Maximum
Turbidity 1.0
NTU
Maximum Silt Density Index
5.0 (based on 15 min. test time)
Maximum Chlorine
less than 0.1 ppm
Maximum
TDS 1500
ppm
Maximum Hardness
16 grains (272 ppm as CaCO3)
Maximum
Iron less
than
0.1
ppm
Maximum Manganese
less than 0.1 ppm
Maximum Hydrogen Sulfide
0 ppm
Langlier Saturation Index
LSI must be negative
*Operating pressure less than 40 psi may require a booster pump:
For manual operation, use BPHF-MO-115 (-230).
For automatic operation, use BPHF-PS-250/4-115 (-230)
*Operating pressure greater than 80 psi will require a pressure regulator.