SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
9
SETUP PROCEDURES
STEP 1: INSTALLATION OF THE HIGH & LOW FLOAT SWITCHES:
A. Install both the High and Low Floats onto an open container, such as a Rubbermaid
®
trash can. The floats
can be mounted by drilling a 5/8" hole. The white washer should be located on the inside of the reservoir.
(The High Float shuts down the system, while the Low Float turns the system on).
B. Connect the floats to the “Y” adapter.
C. Attach the 3-pin connector on the float switches to the UHE CONTROL MODULE. (See image on page 5)
NOTE: Floats are to be mounted horizontal when dry and float up when wet. In most instances we recommend
locating the low float approximately halfway down your reservoir. DO NOT OVERTIGHTEN when
installing the floats.
NOTE: Floats must be installed in the FRESH WATER storage container.
This system MUST be connected to the floats to operate properly.
Failure to install the pure water flush connection for this unit will void any warranty.
STEP 2: CONNECT BULKHEAD FITTING:
(Bulkhead Fitting MUST be installed on the same container as the floats. See Diagram above.)
NOTE:
DI input Float Valve
should be mounted
higher than the High
Float but offset to one
side so it won’t interfere
with the High Float.
3/8" BULKHEAD FITTING:
Use a paddle bit and carefully drill a 13/16"
hole for installation at the bottom of the
reservoir (below the low level float).
(Setup Procedures are continued on next page)