6
The MaxCap
®
RODI system comes equipped with two Dual Inline TDS
monitors. The two TDS meters can monitor every step in the purification
process. The IN probe of the left side meter shows the tap water TDS. The
OUT probe of the left-side meter shows the RO water TDS. The IN probe
of the right-side meter shows the TDS coming out of the MaxCap DI and
the OUT probe of the right-side meter shows the TDS of the final product
water (out of the SilicaBuster DI).
A pressure - operated Shutoff Valve and a Float Valve are provided for
convenient filling of a storage reservoir.
A Manual Flush Valve (-MF) may be used to periodically rinse the
accumulated impurities and concentrated waste water from the surface of
the RO membrane to help increase the life of the membrane. If increased
pressure is needed or desired, use the BPHF-MF-115 Booster Pump Kit for
-MF Systems. This kit has a 24VDC, 2.5A Power Supply.
An Automatic Flush System (-AF) may be used to periodically rinse the
accumulated impurities and concentrated waste water from the surface
of the RO membrane to help increase the life of the membrane. This
system will flush the membrane at startup, every hour, and at shutdown.
If increased pressure is needed or desired, use the BPHF-AF-115 Booster
Pump Kit for -AF Systems. This kit has a 24VDC, 2.5A Power Supply.
Notice:
Drinking water add-on kits and bladder tanks are
not compatible with Automatic Flush (AF) systems.