Temperature Correction Factor Table (TCF)
°F /°C
TCF
°F /°C
TCF
°F /°C
TCF
41.0 /5
0.521
59.0 /15
0.730
77.0 /25
1.000
42.8 /6
0.540
60.8 /16
0.754
78.8 /26
1.031
44.6 /7
0.560
62.6 /17
0.779
80.6 /27
1.063
46.4 /8
0.578
64.4 /18
0.804
82.4 /28
1.094
48.2 /9
0.598
66.2 /19
0.830
84.2 /29
1.127
50.0 /10
0.620
68.0 /20
0.857
86.0 /30
1.161
51.8 /11
0.640
69.8 /21
0.884
87.8 /31
1.196
53.6 /12
0.661
71.6 /22
0.912
89.6 /32
1.232
55.4 /13
0.684
73.4 /23
0.941
91.4 /33
1.267
57.2/14
0.707
75.2 /24
0.970
93.2 /34
1.304
Membrane Output Calculation Example
What is the expected GPD from a 100 GPD System at 40 psi pressure and
60°F water temperature?
PCF = 40 ÷ 60 = 0.666
TCF = 0.754 (from Table above)
Expected GPD = 100 × 0.666 × 0.754 = 50.2 GPD ± 15%
50.2 GPD would be the Actual Production Rate
TIPS FOR LONG MEMBRANE LIFE:
1. Replacement of sediment filter at least once every 6 months.This will
prevent mem brane fouling due to silt or sediment depositing on the
membrane.
2. Replacement of carbon block filter at least once every 6 months or
when chlorine breakthrough occurs. This will ensure good membrane
life and protect the membrane from chlorine damage.
3. Membrane should not be operated at lower than the minimum 2:1
concentrate to purified water ratio.
4. Operating reverse osmosis systems on softened feed water greatly
reduces the chances of membrane fouling.
5. Use the flush valve
after each use
of the system to extend membrane
life. It can be operated even when the system has been turned off. This
is especially useful in hard water conditions.