FLOAT VALVE ILLUSTRATION:
HOW THE FLOAT SYSTEM WORKS:
The increasing water level raises the Float Valve in the reservoir and stops
the flow of water. Pressure builds up in the product line and ASO Valve
until the ASO Valve shuts off the flow of waste water to drain. Now that
BOTH the waste and product lines are blocked off, this “OFF” condition
will be maintained until the reservoir needs more water and the Float
Valve drops, relieving the pressure on the ASO Valve and allowing both
product and waste water to flow again.
NOTE: This configuration maintains tap water pressure in the prefilters,
membrane, and pressure gauge when in the “OFF” condition. Also, this
system WILL NOT WORK with any kind of “bladder tank” attached to the
product line.
An optional float kit may be used for filling an additional sump or reservoir.