![SpectraLink MOG500 Installation And Setup Download Page 13](http://html.mh-extra.com/html/spectralink/mog500/mog500_installation-and-setup_1343831013.webp)
SpectraLink Corporation
Open Application Interface Gateway Installation and Setup
Link WTS – Link 150 MCU
4. Assign OAI Function Key
To access the OAI application, the user presses
FCN
and an assigned number key. Follow
these steps to assign a function key to initiate the OAI application.
1. Make sure a Link Wireless Telephone is registered to line 2. This is the only port
with administration access.
2. With the system up and running and within range of a Base Station, move the
Mode
switch on the MCU to the
ADMIN
position.
3. Press
START
on the Wireless Telephone registered to line 2. You should hear a
steady tone.
4. Press the
FCN
key followed by the key you want to assign for OAI access.
5. Press
##
555
, then press
END
. This assigns OAI to the specified key.
6. Return the MCU
Mode
switch to the
NORM
position.
The OAI macro can be programmed to more than one key sequence to support multiple
OAI functions within the same application. The application must then be able to
distinguish which key sequence is assigned to which function.
Part Number: 72007507B.doc
Page 13