![SpectraLink MOG500 Installation And Setup Download Page 12](http://html.mh-extra.com/html/spectralink/mog500/mog500_installation-and-setup_1343831012.webp)
SpectraLink Corporation
Open Application Interface Gateway Installation and Setup
Link WTS – Link 150 MCU
3.4 Connect the OAI Gateway to the Application Server
Using a standard 9-pin female D-type connector, connect the serial port on the front panel
of the OAI Gateway to the PC, application server, or modem that will be used to interface
with the application.
The OAI Gateway uses the following pins on the connector:
Pin Function
2
Data OAI Receives
3
Data OAI Transmits
5 Ground
If the application is up and running, the
RD
and
SD
LEDs on the front panel of the OAI
Gateway should be lit or blinking, indicating that the OAI Gateway is sending and
receiving data to or from the PC.
Part Number: 72007507B.doc