Section 4: Software Commands
Page 4-20
8197 Instruction Manual
4.2.15 SIGNATURE
CONTROL
The command
SC
reads or selects the Signature Control feature. Signature
Control removes the front and rear panel 10-MHz outputs whenever a Major
Alarm is asserted. The Model 8197 is factory shipped with Signature Control off.
To read the Signature Control configuration issue the
SC
command as follows:
Type:
SC <ent>
Response:
SIGNATURE CONTROL ON
- OR -
SIGNATURE CONTROL OFF
To enable Signature Control place the unit in Set Mode and issue the
SC
command as shown below:
Type:
SC ON <ent>
Response:
SIGNATURE CONTROL ON
- OR -
Type:
SC OFF <ent>
Response:
SIGNATURE CONTROL OFF