Section 4: Software Commands
8197 Instruction Manual
Page 4-15
4.2.11 EVENT
OUTPUT
The Model 8197 maintains logs on alarm conditions, satellite tracking, oscillator
performance and corrections. Entries made to these logs are automatically
output to the RS-232 port they are generated. The
Event Output
command,
EO
,
can enable or disable the automatic output of these entries. The factory default
is enabled.
To view the Event Output configuration issue the
EO
command as follows:
Type:
EO<ent>
Response:
EVENT OUTPUT ENABLED
-
OR
-
EVENT OUTPUT DISABLED
To enable or disable the
Event Output
feature, place the unit in Set Mode and
issue the following command:
Type:
EO ON<ent>
Response:
EVENT OUTPUT ENABLED
-
OR
-
Type:
EO OFF<ent>
Response:
EVENT OUTPUT DISABLED