Speco PVS-3 Operation Manual Download Page 10

charges. Article 810 of the National Electrical Code, 
ANSI/NFPA 70, provides information with regard to proper 
grounding of the mast and supporting structure, grounding 
of the lead-in wire to an antenna discharge unit, size of 
grounding conductors, location of antenna-discharge unit, 
connection to grounding electrodes, and requirements for 
the grounding electrode. See ILL. 1. 

(16) 

Lightning - 

For added protection for this product during a 

lightning storm or when it is left unattended and unused for 
long periods of time, unplug it from the wall outlet and 
disconnect the antenna or cable system. This will prevent 
damage to the product due to lighting and power-line 
surges. 

(17) 

Power Lines –

 An outside antenna system should not be 

located in the vicinity of overhead power lines or other 
electric light or power circuits, or where it can fall into such 
power lines or circuits. When installing an outside antenna 
system, extreme care should be taken to keep from 
touching such power lines or circuits as contact with them 
might be fatal. 

(18) 

Overloading - 

Do not overload wall outlets, extension 

cords or integral convenience receptacles as this can 
result in a risk of fire or electric shock. 

(19) 

Object and Liquid Entry - 

Never push objects of any kind 

into this product through openings as they may touch 
dangerous voltage points or short-out parts that could 
result in a fire or electric shock. Never spill liquid of any 
kind on the product. 

6-4-2  CHANNEL 

The following items can be adjusted or programmed on 
this menu screen. Press PIP/Menu Button again, the 
following menu screen will be displayed. 

 

[CHANNEL] 

 

TITLE DWELL  ALM  LOAD 

 
CH1      :    C 1      03SEC      N/O        75 
CH2      :    C 2      03SEC      N/O        75 
CH3      :    C 3      03SEC      N/O        75 
CH4      :    C 4      03SEC      N/O        75 
QUAD :                03SEC      N/O        75 
EXIT                    [ 

 ] 

 

 
 
 
 
 

CHANNEL MENU

 

 

a.  CAMERA TITLE 

- Place the green color character to the date digit using the 

 and the 

 Buttons and press the VCR / Enter 

Button. The first empty box will be flashing   

- Select the position you want to enter the letter or the 

numeric number using the 

 Buttons. 

 and the 

 Buttons is to change the new character. 

-  Press the VCR / Enter Button to return to the menu. 

You can enter up to 8 characters for each camera title. 

 

 b.  DWELL TIME

 

Dwell Time is the amount of time that a camera is 
displayed on the screen, before switching, when the 
system is in the Automatic sequential switching mode. The 
Dwell Time can be adjusted individually for each camera 
and the quad display from 0 to 59 seconds. When it is set 
to be zero (OFF) the corresponding camera will be 

                         PVS - 3           PVS - 

  - 07 -                                                                                                                                                                                                                                                - 28 - 

Summary of Contents for PVS-3

Page 1: ...rvation System 14 Monitor with Built In Quad Splitter And 4 CH Switcher With enhanced audio output speco technologies 200 New Highway Amityville NY 11701 Toll Free 1 800 645 5516 In Metro NY 631 957 8...

Page 2: ...anying the appliance THE GRAPHIC SYMBOLS WITH SUPPLEMENTAL MARKING IS APPLIED ON THE REAR SIDE OF THE SUBJECT MONITOR WARNING To prevent fire or shock hazard do not expose this appliance to rain water...

Page 3: ...30 seconds and then turn it ON again INDEX SECTION 1 1 PURPOSE OF THIS PRODUCT 1 2 FEATURES SPECIFICATIONS 2 2 1 Monitor Features 2 2 2 Specifications 2 3 IMPORTANT SAFEGUARDS 4 SECTION 2 4 CONNECTION...

Page 4: ...table borderline Motion function available option 7 1 Function select keys 1 Turns Power to monitor ON OFF 2 1 4 Allows user to select individual cameras 3 FRZ 1 When the user wants to freeze the CH1...

Page 5: ...op through VCR input Horizontal resolution Center 380 lines NTSC PAL Corner 340 lines NTSC PAL Comb filter Improves picture quality significantly Functions Tint color contrast brightness sharpness aud...

Page 6: ...nnector video in 6 pin mini DIN video in audio in out 12V DC out alarm PIR in RCA jack VCR in out slave video audio out Power Source AC 90V 240V 50 60Hz 65W Free Voltage Switching Power Supply Dimensi...

Page 7: ...al symbols explanation but before and separated in format from the other material The instructions need not be in the order shown and they need not be verbatim The use of a different font for the indi...

Page 8: ...by placing the product on a bed sofa rug or other similar surface This product should not be placed in a built in installation such as a bookcase or rack unless proper ventilation is provided or manu...

Page 9: ...current plug a plug having one blade wider than the other This plug will fit into the power outlet only one way This is a safety feature If you are unable to insert the plug fully into the outlet try...

Page 10: ...t in a risk of fire or electric shock 19 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts that co...

Page 11: ...ing to qualified service personnel 21 Damage Requiring Service Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the pow...

Page 12: ...ME Place the cursor to the time digit using the or the buttons and press the ENTER button to flash the TIME 00 00 00 and set it using the or the buttons Press the VCR Enter Button again to stop flashi...

Page 13: ...03SEC N O 75 QUAD 03SEC N O 75 EXIT DISPLAY TIME 00 00 00 DATE 01 01 2004 MM DD YY DATE FORMAT YY TIME DISP MON VCR E VCR OUT QUAD TITLE DISP Y QUAD LINE Y BLANK COLOR BLU EXIT BUZZER ALARM KEY BUZZE...

Page 14: ...menu or OSD of Volume disappear AUDIO SEL button selects a channel where you wish to hear in the Quad mode TALK button is to enable the voice communications between the monitor s place and the camera...

Page 15: ...seconds The monitor will automatically return to the QUAD mode after the alarm hold time 00 to 59 seconds is completed Button CH1 CH2 CH3 and CH4 are to select a channel to view in full screen size i...

Page 16: ...TO mode Press Quad Auto 1 Zoom Button it displays C1 C2 C3 and C4 orderly from QUAD screen AUTO PIP mode AUTO2 Displays PIP mode and you can choose the main channel with sub channel sequencing in orde...

Page 17: ...select four different ZOOM pictures by using VCR ENTER Button 6 VCR AUDIO IN RCA connector to receive audio from VCR VCR VIDEO IN RCA connector to receive audio from VCR C 1 01 01 2004 00 00 00 C 2 P...

Page 18: ...tch on this monitor A quadrant picture should be seen on the monitor A quadrant picture should be seen on the monitor 6 2 CHANGE DISPLAY MODE 6 2 CHANGE DISPLAY MODE When monitor is reset or power is...

Page 19: ...VCR or a Time Lapse Recorder Perform following steps to install the monitor with them VCR REAR VIEW OFF O INSTALLATION OF A VCR C1 01 01 2004 00 00 00 C1 01 01 2004 00 00 00 N AC INPUT 90 250V 50 60Hz...

Page 20: ...turer s instructions 5 3 Installation with Sensors This monitor has the capability to receive alarms and activate a recorder or other external alarm device when a sensor is activated Perform following...

Reviews: