Chapter 2
Connections
Connections diagram
Important
•
When connecting devices or making changes, be sure to turn the POWER switch OFF and disconnect the power cord from the
electrical outlet. Plug in the power cord last.
•
If an extremely loud signal is input to this product, there is a danger that noise will be generated and cause damage. In such a case,
lower the input signal level.
•
Use only the included DC cords for the connection between the amplifier and power supply. Do not use any other cords. Be careful not
to mistake the MAIN DC cord and the SUB DC cord.
■
When MONO mode (mono connection)
•
Set the
9
SPEAKERS selector switch to [1]. (
page 11)
•
When a playback device is directly connected to the product, the volume of the product can be adjusted by connecting the volume
controller (H-VC5) (sold separately) to the SPEC-VOL CONT terminal. Set the
3
GAIN selector switch to [SPEC-VOL]. (
page 11)
•
When a control amplifier is connected to the product, set the
3
GAIN selector switch to [MAX] or [-6 dB]. (
page 11)
•
For this connection, always connect a speaker to the speaker 1 terminal. No sound will be output from the speaker 2 terminal.
H-VC5
Speaker system
To the speaker terminals
To the audio
output terminal
To the balanced
output terminals
Control amplifier, etc
To AC IN
To the electrical outlet
* Depending on the control amplifier used, there may be a caution regarding simultaneously connecting RCA and XLR, so refer to the
operation manual of the respective control amplifier.
5