Spearhead TWIGA
120
24
24
24
24
HYDRAULIC SYSTEM
HYDRAULIC SYSTEM
HYDRAULIC SYSTEM
HYDRAULIC SYSTEM
(Machines Equipped with Pump and Tank Kit)
(Machines Equipped with Pump and Tank Kit)
(Machines Equipped with Pump and Tank Kit)
(Machines Equipped with Pump and Tank Kit)
Tank
The machine is delivered from the factory without oil. Fill the reservoir with a light hydraulic
oil as recommended in the chart below until the oil level is approximately 2" below the top
of the tank. The total capacity is approximately 23 litres (5 galls) Do not overfill. For ease
of filling when large quantities are involved the strainer basket can be prized from its
housing. If filling in this manner make sure that new oil is used and that the area around
filler and any filling utensils are clean.
SUPPLIER
COLD OR TEMPERATE
CLIMATE
HOT CLIMATE
BP
Bartran 46
Energol HLP-HM 46
Bartran 68
Energol HLP-HM 68
CASTROL
Hyspin AWH-M 46
Hyspin AWH-M 68
COMMA
Hydraulic Oil LIC 15
Hydraulic Oil LIC 20
ELF
Hydrelf HV 46
Hydrelf XV 46
Hydrelf HV 68
ESSO
Univis N 46
Univis N 68
FUCHS
(UK/Non UK markets*)
Renolin 46
Renolin HVZ 46
Renolin CL46/B15*
Renolin AF46/ZAF46B*
Renolin 68
Renolin HVZ 68
Renolin CL68/B20*
Renolin AF68/ZAF68B*
GREENWAY
Excelpower HY 68
Excelpower HY 68
MILLERS
Millmax 46
Millmax HV 46
Millmax 68
Millmax HV 68
MORRIS
Liquimatic 5
Liquimatic HV 46
Triad 46
Liquimatic 6
Liquimatic HV 68
Triad 68
SHELL
Tellus 46
Tellus T46
Tellus 68
Tellus T68
TEXACO
Rando HD 46
Rando HDZ 46
Rando HD 68
Rando HDZ 68
TOTAL
Equivis ZS 46
Equivis ZS 68
Oil Supply
Check daily the oil level in the reservoir. No fixed time period can be quoted for oil
changes as operating conditions and maintenance standards vary so widely. Although the
oil does not wear out, it does eventually break down through contamination, oxidation and
condensation. Continual operation of the machine beyond its rated capacity to almost the
stall point of the cutter can cause overheating which produces insoluble gums, sludge,
varnish and acids. Overheated oil thins to give a sluggish performance and causes earlier
failure of seals and 'O' rings. Burnt and scorched oil odours and the oil darkening and
thickening are all signs of oxidation and indicate the oil should be changed. Moisture which
results from condensation can become entrapped in the oil and cannot be removed by
filtration so that contamination is a progressive factor. Contamination of the oil can be
reduced by:
• Performing all hydraulic servicing in a clean, dry, dust-free environment.
• Cleaning around the reservoir cap prior to its removal and keeping that area clean.
• Using clean containers when replenishing the system.
•Regular servicing of the filtration system
Summary of Contents for TWIGA 120
Page 33: ...Spearhead TWIGA 120 32 32 32 32...