Speakman SV-3005 Installation Instructions Manual Download Page 4

The factory set range is 25-1/2”. Sensors in the wash closet models are pointed 15 degrees up,

while urinal sensors are pointed 15 degrees down.

A

B

C

CALIBRATE THE SENSOR

A.

 Remove the protective film covering the Sensor Eye. 

B. Test the Sensor by standing in front the Flushometer for about 10 seconds, then stepping away 
from the Sensor. 

C. You should hear a click as the Solenoid actuates, and see a red-light flash in the Sensor Eye.

16

C

D

B

A

1/2 TURN

TIGHTEN CONNECTIONS

A. Using a Flat Tip Screwdriver, slowly open the Control Stop by about ½ turn. A flush sequence 
should begin immediately. 

B

. Use this time to check for leaks or any loose connections. 

C

. Continue to loosen the Control Stop Adjustment Screw until desired flush sequence is achieved.

D

. Test the Flushometer by activating the Sensor, or by pressing the manual override button for 

1 second.

  

• A flush sequence should begin again.

 

• Continue to operate the Flushometer until desired flow is achieved, it may take a few  

 

  actuations for the flushometer to become hydraulically balanced, this is normal.

17

REINSTALL CONTROL STOP COVER

Reinstall the Control Stop Cover using the included 2.5mm Hex Key Wrench.

18

CALIFORNIA PROPOSITION 65

CALIFORNIA PROPOSITION 65:

WARNING: 

This product can expose you to chemicals including lead, which is known 

to the State of California to cause cancer and birth defects or other reproductive harm. 
For more information go to www.P65Warnings.ca.gov.
Wash hands after installation, repair, or removal of this product.

PRODUCT WARRANTY

This product is warranted to be free of defects in material and workmanship for the period listed 
below from the date of installation.

 

Consumer/Residential: Limited Lifetime Warranty

 

Commercial Use: 5 Year Limited Warranty

Speakman warrants to its purchasers only (“Buyer”) that goods are sold free from defects in materials and 
workmanship and conform to Speakman’s specifications at the time of manufacturing, provided the goods 
are properly installed and maintained. Buyer’s sole and exclusive remedy for any goods that may prove to 
have had a non-conformance within the Warranty Period shall be, at Speakman’s sole option, the repair or 
replacement of the non-conforming goods. For additional information please go to www.speakman.com.

Summary of Contents for SV-3005

Page 1: ... Breaker Repair kits are available for purchase for each of the components given above as well as components that will need to be serviced less frequently such as the spud nut assembly and inlet piping assembly See Repair Parts section of this document for a full list of repair kits that are offered for this product NOTE Regulations prohibit using replacement parts for this product that would incr...

Page 2: ...osed by turning Adjustment Screw clockwise until fully seated B Slowly turn ON water supplies and inspect for leaks and piping issues C Hold a bucket or catch basin at the outlet of the Control Stop Slowly open the Control Stop Adjustment Screw by turning a Flat Tip Screwdriver counter clockwise and flush out any debris D Return the Adjustment Screw to a fully closed position 7 B A VERIFY VACUUM B...

Page 3: ...e Assembly B Tighten the connection between the Valve Body and Control Stop C Tighten the connection between the Tailpiece Assembly and Spud Nut 12 C A B E D ACCESS BATTERY BOX A From behind the Valve Body loosen but do not remove the Set Screw with the included 2 5mm Hex Key Wrench B Lift off the Valve Body Cover C Disconnect the BLACK wire connection to the Solenoid D Remove the Battery Box from...

Page 4: ...cally balanced this is normal 17 REINSTALL CONTROL STOP COVER Reinstall the Control Stop Cover using the included 2 5mm Hex Key Wrench 18 CALIFORNIA PROPOSITION 65 CALIFORNIA PROPOSITION 65 WARNING This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ...

Page 5: ...05 118137 PISTON KIT SV 3010 SV 3110 RPG05 118139 PISTON KIT SV 3005 SV 3105 RPG05 118142 VACUUM BREAKER KIT RPG05 118161 AA BATTERY BOX RPG11 118155 MANUAL OVERRIDE KIT RPG11 118156 MANUAL OVERRIDE INTERNAL KIT RPG11 118157 MANUAL OVERRIDE GASKET AND SEAL KIT RPG11 118158 MANUAL OVERRIDE COVER KIT RPG20 118129 SENSOR AND VALVE COVER KIT SV 3005 RPG20 118131 SENSOR AND VALVE COVER KIT SV 3010 RPG3...

Page 6: ...e per Second a The batteries have been used up The batteries must be replaced 4 The Flush Valve is Flushing Continuously or Does Not Shut Off a Check for an audible click from the solenoid i If there is an audible click proceed with troubleshooting step 4 b ii If there is no audible click order a replacement solenoid b The bypass in the valve body is likely clogged with debris or build up from the...