• Connect with other units to extend your signal over long distances
• Equalized and re-clocked
• Supports signal input and output distance of up to 300M for SD
signals, 200M for HD signals and 100M for 3G signals.
NOTE
Cable tested with Belden 1694A. Operating distances may vary if
used with another type of cable.
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
LCM Monitor
This LCM monitor display the input and output selection and the
upper line is displaying output A, B, C, &D where as the lower line is
displaying each output’s input selection.
IR receiver
This IR window receives IR signal from the remote control included
in the package.
OUTPUT Button
Press this button to select the output A~D the cursor will jump
on the lower line of the LCM monitor then, select a input for the
cursor’s pointed output.
INPUT -/+ Button
Press – or + button to select the input sources from 1~16, after the
selection press ENTER to confirm the option.