USER’S MANUAL
EN
17
8.4.5.2 Removing the battery
Press the retaining button on the bottom right side and pull it out until it is completely
removed from the blower unit.
8.4.5.3 Charging the battery
The charger has been equipped with a system of variable plugs for the socket
(4 pieces: UK, SAA,
USA and EU)
. Supports supply voltages from 100 to 240V AC 50/60Hz ± 10%.
1.
Check what type of outlet is present in your power supply installation.
2.
Choose the right plug and make sure that the electrical connection meets
the charger specifications.
3.
To change to an alternative plug, press the button „PUSH” and pull the plug away in the
opposite direction from the cord. Insert the appropriate plug until the clip snaps into place.
4.
Connect the battery to the charger. The charging process is signalled by the yellow illuminated
LED on the charger. After charging has been completed, the LED turns green and the trickle
charging mode is activated.
SAFETY INSTRUCTIONS:
1. Use the charger only with recommended batteries.
(You cannot charge any battery with any charger).
2. Batteries should be charged at room temperature from 10°C to 30°C.
3. It is forbidden:
a. using a charger outside the building,
b. exposing the charger to high temperatures,
c. storing the charger in humid conditions,
d. cover the charger during operation,
e. charging the battery repeatedly without first discharging it,
f. opening / dismantling the charger (except for the socket plug change described in
the manual),
g. using the charger in an explosive and / or potentially explosive atmosphere,
h. installation of a charger to an electric network that does not meet the specified parameters.
4. It is recommended not to leave the charger switched on without a load.
5. Remember that any electrical device should not be operated unattended.
8.4.6 Alarm system
Periodically check the low airflow alarm to check its functionality. This test should be carried
out with a fully charged battery and unblocked filter and hose in a clean area. To test the alarm
switch the unit on disconnect the hose from the welding helmet and place the palm of the
hand over hose. Within 15 seconds the alarm will sound and the red Air Flow LED will illuminate.
Immediately remove your hand from the hose. The alarm will automatically switch off. Reconnect
the hose to the helmet.