Spartherm Mini Z1 H2O Installation And Operating Manual Download Page 3

- 5 - 

1. General information 

 

Before assembling and installing the H

2

O fireplace insert you should 

meet with the master chimney sweep responsible for such matters in 
your area.

 He will advise you on the building regulations and suitability of 

your chimney and will carry out the acceptance test on your fireplace 
insert. The chimney calculation is based on DIN EN 13384 using the value 
specifications table contained in this manual (see Specification 1.2) 

(DECLARATION OF PERFORMANCE MAY BE VIEWED AND IS 
AVAILABLE FROM WWW.SPARTHERM.COM)

 

 

Young children, the elderly and the frail, and pets: 

as with all heating 

devices, a guard should be fitted to protect the above because both the 
glass door and the fireplace covering can become very hot.  
 

 

Risk of burns

  

 

Never

 leave a fireplace unsupervised when the fire is burning or when it 

has just gone out. Do not leave the fireplace unattended for prolonged 
periods of time. 
 

CAUTION:  The protective glove supplied is designed only for 
protection from heat when operating the control handle and the 
cold hand. The glove is not fireproof.  

 
When assembling and operating your fireplace insert and when connect-
ing it to the chimney you must ensure that you comply with national and 
European standards, the relevant country-specific and local guidelines 
and regulations, and in particular, in Germany, the relevant Heating 
Regulation (FeuVO) of the state where you live. 
 
To make better utilisation of the high flue gas temperatures, a water heat 
exchanger is integrated in the linings and in the flue gas collector. A hot 
water storage tank or buffer storage tank, etc., can be heated with the hot 
water generated. If these or similar system components are not available 
then other structural measures must be taken to ensure safe, constant 
heat dissipation. 
 
Generally speaking, the fireplace must be used with a door that closes 
automatically. No modifications to the closing device are permitted. No 
additional heat exchangers, supplementary heating surfaces, etc, which 

- 6 - 

extract heat from the flue gas, may be incorporated into the connecting 
pipe to the chimney. 
The H

2

O fireplace insert is intended as an auxiliary heat generator for 

water heating systems in accordance with DIN EN 12828, since the 
nominal heat output is only maintained as long as the fireplace insert is 
stoked to its nominal heat output. 
The fireplace may only be used with suitable combustion control systems 
adjusted as appropriate. Please consult Spartherm Feuerungstechnik 
GmbH as necessary. 
 

Never use the H

2

O fireplace insert without water

.

 

 

1.1. Scope of supply 

 

H

2

O fireplace insert with the following characteristics: 

 

  Fireplace insert with integrated water heat exchanger, vertical sliding 

door or hinged door. 

  Safety heat exchanger and bleed valve(s) 

  ¾” overheat discharge valve with ½” immersion sleeve and 4 m length 

of capillary tubing, e.g., SYR 3065 (Mini Z1 H

2

O /XL, Varia 1V H

2

O and 

Varia 1V H

2

O XL/XLL) 

  ¾” overheat discharge valve with ½” immersion sleeve and 4 m 

length of capillary tubing, e.g., Watts TST 2005 (Varia 2/L/2R H

2

O)  

  ¾” overheat discharge valve with ½” immersion sleeve and 2 m length 

of capillary tubing, e.g., Watts (Varia Ah H

2

O and Varia A-FDh H

2

O) 

  Immersion sleeve for the thermostat switch 

  50 mm x 30 mm cleaning brush 

  Flue gas connection (swivel) 

  Thermostat switch for circulating pump, including capillary tubing 

(length = 1.5 m): JUMO, heatTHERM 602030 type  

  Housing thermostat for circulating pump with capillary tubing (length = 

2.0 m): Afriso GTK7/HK with 3.0 m of temperature-resistant connecting 
cable (Varia 2Lh / 2Rh H

2

O, Varia Ah H

2

O and Varia A-FDh H

2

O) 

 

The following components are available as an option: 

  Load unit (ESBE, LTC 141 type) 

  Accessories for the heating installations, e.g., safety valves, expansion 

vessels, pressure gauges, etc.  

  S-Thermatik, combustion control system with temperature display, 

e.g., for the buffer storage tank temperature   

  S-Thermatik, combustion controller allowing variable settings and up to 

five temperature indications. 

Summary of Contents for Mini Z1 H2O

Page 1: ...on the good name of our firm is inextricably linked to the credo of our owner Gerhard Manfred Rokossa High technical quality combined with modern design and on site customer service carried out to the...

Page 2: ...ncorporation into a heating system 38 2 11 Chimney connection connecting piece 53 2 12 Height limitation door stop 53 3 Initial commissioning 56 4 Operation 57 5 Cleaning and maintenance 59 5 1 Cleani...

Page 3: ...o modifications to the closing device are permitted No additional heat exchangers supplementary heating surfaces etc which 6 extract heat from the flue gas may be incorporated into the connecting pipe...

Page 4: ...O Varia A FDh H 2 O Unit Weight empty without accessories 235 235 245 330 350 380 395 396 kg Nominal output range 4 9 9 1 7 13 7 7 14 3 10 18 7 14 8 27 5 10 3 19 7 3 13 5 7 3 13 5 kW Nominal heat out...

Page 5: ...9 Mini Z1 H2O Fig 1a 10 Mini Z1 H2O XL Fig 1b...

Page 6: ...11 Mini Z1h H2O XL Fig 1c 12 Varia 1V H2O Fig 1d...

Page 7: ...13 Varia 1Vh H2O Fig 1e 14 Varia 1V H2O XL Fig 1f...

Page 8: ...15 Varia 1Vh H2O XL Fig 1g 16 Varia 1V H2O XXL Fig 1h...

Page 9: ...17 Varia 1Vh H2O XXL Fig 1i 18 Varia 2Lh 2Rh H2O Fig 1j...

Page 10: ...19 Varia Ah H2O Fig 1k 20 1 Abgaskuppel 2 separater Verbrennungsluftstutzen 150 mm 3 Luftstellhebel 4 T r klappbar 5 T r hochschiebbar Varia A FDh H2O Fig 1l...

Page 11: ...nstallations must be checked for leaks by means of a pressure test For this purpose the H2O fireplace insert must be aligned horizontally by adjusting the height of the fireplace insert feet or provid...

Page 12: ...any All the work must be carried out according to the VDE Regulations e g VDE 0105 VDE 0116 VDE 0100 etc and the technical connection require ments of the local power supply company 2 3 H2O fireplace...

Page 13: ...ve G feed of overheat discharge valve H rear bleed valve I return J inspection opening Fig 2a 26 Varia 1V H2O Varia 1Vh H2O To facilitate access to the water connections of the Varia 1V H2O an inspect...

Page 14: ...l sensor D bleed valve E return F feed of overheat discharge valve G discharge of overheat discharge valve Fig 2c 28 Varia 2Lh 2Rh H2O For access to the water connections of the Varia 2Lh 2Rh H2O an i...

Page 15: ...connections are clearly marked and must not be used for any other purpose The integral safety device safety heat exchanger must not be used to heat water We recommend the use of straight or angled rad...

Page 16: ...1V H2O Varia 1Vh H2O Varia 1V H2O XL Varia 1Vh H2O XL Varia 1V H2O XXL Varia 1Vh H2O XXL 600 cm 750 cm Varia 2Lh 2Rh H2O 600 cm 750 cm Varia Ah H2O 440 cm 400 cm Varia A FDh H2O 220 cm 200 cm Generall...

Page 17: ...safety device from operating Furthermore all the required safety devices must be integrated throughout the system in such a manner as to ensure non hazardous operation A separate safety valve must sti...

Page 18: ...ks at any time The discharge of the overheat discharge valve must be executed in such a manner that a test may be carried out at any time e g via an outlet with siphon 36 2 9 Thermal pump control syst...

Page 19: ...cted phase L blue wire 2 10 Incorporation into a heating system Please note The H2O fireplace insert may only be installed in a complete system after detailed planning for the entire heating system ac...

Page 20: ...ire storage tank takes just under 2 hours On very cold winter days the fireplace system may be in operation for as much as 12 hours or so The thermal energy produced in such a case is then theoretical...

Page 21: ...for the thermostat switch C feed D safety valve 3 bar E bleed valve F pump thermostat switch e g JUMO heatTHERM G Load unit H load unit fittings e g ESBE type LTC 141 I circulating pump J filling and...

Page 22: ...sor for the thermostat switch D safety valve 3 bar E return F pump thermostat switch eg JUMO heatTHERM G return H load unit fittings e g ESBE type LTC 141 I circulating pump J filling and drain fittin...

Page 23: ...valve B temperature sensor for the thermostat switch C safety valve 3 bar D bleed valve E pump thermostat switch eg JUMO heatTHERM F return G load unit fittings e g ESBE type LTC 141 H circulating pum...

Page 24: ...D return E discharge from overheat discharge valve F supply to overheat discharge valve G safety valve 3bar H bleed valve I pump thermostat switch eg JUMBO heatTHERM J return K load unit fittings e g...

Page 25: ...ermal safety heat exchanger discharge F Thermal safety heat exchanger feed G bleed valve 3 8 H safety valve I bleed valve 3 8 J pump thermostat switch e g JUMO heatTHERM K heating system connection L...

Page 26: ...valve I bleed valve 3 8 J pump thermostat switch e g JUMO heatTHERM K heating system connection L load unit M return N load unit fittings e g Thermoventiler AB type Laddomat 21 O circulating pump P fi...

Page 27: ...ening height is reduced by 50 mm If the opening height is to be further reduced reduction in opening height by 100 mm or increased maximum opening the stops on both sides of the door must be converted...

Page 28: ...and the vermiculite are slowly tempered and the moisture from any storage transport etc slowly evaporated off If this is not done the area between the glass panes may be contaminated and the fireclay...

Page 29: ...s opera tion of the latter When the flue gas temperature is sufficiently high approx 150 C the flue gas valve closes automatically This de flects the flue gas flow through the heat exchanger When the...

Page 30: ...and if our recommendations are followed the cleaning intervals can be significantly extended After the end of the heating season thorough cleaning of all the components is required The heat exchanger...

Page 31: ...nt them in the commission ing log In the event of a claim evidence of the maintenance work carried out must be submitted to the service personnel 62 6 Troubleshooting Note The fireplace must not be us...

Page 32: ...ween the manufacturer Spartherm Feuerungstechnik GmbH and the dealer intermediary They are not the same as the contract and warranty terms and conditions which the dealer intermediary passes on or may...

Page 33: ...ur or other aspects due to thermal stress improper transport and or incorrect storage 66 improper handling of fragile components such as glass and ceramics improper handling and or use lack of mainten...

Page 34: ...em bled Yes No Working pressure checked Yes No System tested for leaks Yes No All safety devices overheat discharge valve safety valve diaphragm expansion vesssel tested Yes No Please enter temperatur...

Reviews: