Pilot Flame
Thermopile
CLEANING AND MAINTENANCE
BURNER, PILOT AND CONTROL COMPARTMENT
Keep the control compartment clean by vacuuming or brushing at least twice a year.
Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times.
PILOT FLAME
The flames from the pilot should be visually checked as soon as the
unit
is installed
and periodically during normal operation.
The pilot flame must always be present
when the fireplace is in operation.
The pilot flame has t
wo distinct flames, one
engulfing the thermopile and the other reaching to the main burner.
BURNER
Inspect area around the injector. Remove any lint or foreign material with a brush
or vacuum.
Turn off gas before servicing fireplace. It
is recommended that a qualified service
technician perform these check-ups at the
beginning of each heating season.
WARNING
Have the venting system of the solid fuel burning fireplace inspected and cleaned
annually by a qualified agency.
1
1
VENTING SYSTEM