Spark modern fires LBS-OD 24 Owner'S Operation And Installation Manual Download Page 8

32                                                                                                                                                       

L100001

  

8

                                                                                        

A.

This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light

the pilot by hand

.

B. 

BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because 
some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

      •     

Do not try to light any appliance. 

      •     

Do not touch any electric switch; do not use any phone in your building.

      •     

Immediately call your gas supplier from a neighbor's phone. 

          

Follow the gas supplier's instructions.

      •     

If you cannot reach your gas supplier, call the fire department.

     

C. 

Main gas valve in this appliance is not servic

e

able and does not have any control knobs or switches to operate.

 

Do not remove heat shield

s

 covering the valve

 

and electronic devices

; do not try to repa

i

r or modify the valve 

as it may result in a fire or explosion.

 Call a qualified service technician if you have any safety concerns. 

D. 

Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician 
to inspect the appliance and to replace any part of the control system and any gas control that has been under 
water.

                                                 LIGHTING

 INSTRUCTION

 FOR YOUR SAFETY READ BEFORE OPERATING 

 

LIGHTING  FOR  THE  FIRST  TIME 

INITIAL LIGHTING 

Purge air from the supply line as follows: 

      •     Open main shutoff valve.
      •     Unscrew main pressure test point.
      •     Leave inlet test screw open until gas comes in.
      •     When gas is flowing, tighten inlet screw immediately. 

LEAK TESTING

1.     Follow the pipe from the gas supply line connection to the gas valve. Check connection for leaks with soap 

and water mixture. 

2.     Next check for gas leaks at the burner with soap and water mixture.

3.     Check the pilot for gas leaks with soap and water mixture.

If you do not follow these instruction exactly, 
a fire or explosion may result causing property 
damage, personal injury or loss of life.

WARNING

Never use an open flame to check for gas leak.

DANGER

Summary of Contents for LBS-OD 24

Page 1: ...ervicing this equipment Improper installation adjustment alteration service or maintenance can cause injury or property damage DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide...

Page 2: ...on or near the appliance 6 Clothing or other flammable high surface temperatures and should stay away to avoid burns or clothing ignition trical Code ANSI NFPA 70 or the Canadian Electrical Code CSA...

Page 3: ...one by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More fre quent cleaning may be required as necessary It is imperative...

Page 4: ...ustible materials Above example is Clearances to combustibles must be maintained see page 3 not a requirement Cover see Illustrated Parts List page 13 must be in place when appliance is not in use min...

Page 5: ...as control inlet is 3 8 NPT A qualified installer or service person must connect appliance to gas supply Follow all local codes WARNING For propane LP units never connect fireplace directly to the pro...

Page 6: ...all undue loss of pressure will occur WARNING Test all gas piping and connections for leaks after installing or servicing Correct all leaks at once WARNING Never use an open flame to check for a leak...

Page 7: ...H W 0 65 11 5 1 2 5 4 N G L P OVERALL 24 41 000 33 500 2 1 44 49 MODEL N G L P ORIF ORIF SIZE N G L P LBS OD 24 NG LP LBS OD 48 NG LP LBS OD 72 NG LP LBS OD 96 NG LP 48 72 96 BURNER TUBE LENGTH 20 44...

Page 8: ...qualified service technician if you have any safety concerns D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance...

Page 9: ...to light the pilot by hand If you don t smell gas go to the next step WARNING 9 7 Turn the gas control manual valve to the ON position 8 Plug supplied 7V DC adapter into 110V power outlet LIGHTING FOR...

Page 10: ...er outlet 3 Turn the gas control manual valve to the full OFF position 1 Turn off all electric power to the appliance if service is to be performed 2 If necessary remove Front Tray from the appliance...

Page 11: ...engulfing the flame sensor and the other reaching to the main burner Pilot Flame Inspect area around the burner Remove any lint or foreign material with a brush or vacuum Keepthecontrolcompartment cl...

Page 12: ...to produce moderate levels of carbon soot where flames Burner is excessively noisy Note The movement and combustion of gas will create low unavoidable levels of noise Burner flame is too low or too hi...

Page 13: ...orifice diameter is too small 4 Flame sensor leads disconnected 1 Pilot flame needs adjusting 1 Gas leak See Warning statement above 1 Gas leak See Warning statement above IMPORTANT Operating unit wh...

Page 14: ...T O W N E R S O P E R A T IO N AN D IN S T A L L A T IO N MAN U AL 14 ILLUSTRATED PARTS LIST ILLUSTRATED PARTS LIST FOR PART DESCRIPTION SEE NEXT PAGE 16 16 18 15 14 1 8 5 2 3 4 6 7 9 10 11 12 13 17 I...

Page 15: ...0028 R100028 R100028 1 5 DFC Wire Assembly H100141 H100141 H100141 H100141 1 6 D400260 D400260 D400260 D400260 1 Part Number according to the LBS OD Natuaral Gas model and Propane LP W120202 W120204 W...

Page 16: ...D400290 D400290 D400290 1 LBS OD 24 LBS OD36 LBS OD 48 LBS OD 60 LBS OD 72 LBS OD 96 R100044 R200062 R100043 R100043 R100043 SEE PAGE 6 R200064 R100062 10 Front Tray D400234 D400254 D400253 D400209 D...

Page 17: ...ON ILLUSTRATED PARTS LIST SEE NEXT PAGE FOR PART DESCRIPTION 2 ILLUSTRATED PARTS LIST SEE NEXT PAGE FOR PART DESCRIPTION ILLUSTRATED PARTS LIST SEE NEXT PAGE FOR PART DESCRIPTION 2 17 PSE NA368 Pilot...

Page 18: ...127 6...

Page 19: ...ance Inside Corner Trees Shrubs Other Termination Please Describe Prevalent Wind Conditions Other Installation Notes The installer should complete the form below that describes the details of the inst...

Page 20: ...pliance and does not extend to 1 firebox burner assembly damaged by accident neglet misuse abuse alterations negligence of others inclu ding the installation thereof by unqualified installers 2 the co...

Reviews: