5
LOCATING FIREBOX
PLANNING
Carefully p
lan where you will install the firebox. This will save time and money later when you install the
firebox.
Before installation, consider the following:
1. Where the firebox will be located. Allow for wall and ceiling clearances (see
Installation Clear-
ances,
page
9
.
2. Everything needed to complete installation.
3.
Proper air for combustion and ventilation.
PRODUCT SPECIFICATIONS
RIGHT SIDE VIEW
60"
48"
28.75"
8.15"
25.75"
28.75"
FRONT VIEW
TOP VIEW
GAS LINE ACCESS, BOTH SIDES
25.75"
13.75"
18"
Maximum
10.5"
Minimum
5.0"
Ignition
Electronic
Manifold Pressure
3.5"
W.C.Inlet Gas Pressure (in. of water)
Type Gas
Propane/LP
Ignition
Electronic
Manifold Pressure
10.0"
W.C.Inlet Gas Pressure (in. of water)
ModeP
Maximum
13.0"
Minimum
11.0"
Btu (V
B
tu (V
ariable)
2
5,500 - 39,000
Type Gas
Natural Gas
ariable)
2
7
,000 - 38,000
Model 5
9
N
Model 5
9
P
Orifice
#49
Shipping
Weight
1
65 lbs.
Orifice
#31
Shipping
Weight
1
65 lbs.