GUARANTEE
! " # #
$ % # % !
FAULT FINDING
FAULT
CHECK
POSSIBLE REASON AND ACTION
REQUIRED
No power to mixer
Check plug socket
Check wiring in plug
Check fuse in plug
Check or change cable
Check circuit breaker over load or
short
Mixer not plugged into a live socket or not switched on
Plug incorrectly wired – rewire correctly
Possible faulty fuse – replace fuse
Cable damaged or split – replace cable
Circuit breaker shut off or constantly short – reset or
replace the circuit breaker (automatically reset).
Mixer becomes noisy
Check bowl and tools
Check work surface
Check the wear of bearing
Ensure that bowl and tool are correctly seated.
Uneven surfaces create excessive resonance.
Worn bearings – replace bearings
Mixer loses power
Check capacity
Overloading of bowl – reduce load
Motor overheating
Check supply voltage
Voltage should correspond to rating plate
Oil on planetary shaft
Check oil seal
Worn oil seal – change oil seal
Mixing tools stuck on
planetary shaft
Check planetary shaft bent,
unclean or rusted.
Planetary shaft twisted or bent – please change planetary
shaft.
Planetary shaft rusted – please use descaler for derusting.
Turn planetary shaft anti-clockwise to meet square
groove, gently knock down mixing tools.
▲
It is recommended that any servicing or maintenance work must be carried out by a trained technician or
electrician.
▲
Isolate the mixer from the electricity supply by removing the plug from the socket before cleaning or
servicing.
▲
Isolate the mixer from the electricity supply by removing the plug from the socket after long
period of no use.