LIGHT BUTTONS

(

) LIGHT ON / MODE BUTTON

ON

OFF

UP

DOWN

(

) LIGHT SPEED / COLOUR

UP

DOWN

OK

[L.BRT] LIGHT BRIGHTNESS

UP

DOWN

Two light buttons are used to control the many
features of the multi colour LED spa light.

Press to toggle light

and

. The button is

backlit green to indicate when the light has been
turned ON.

When the light is first turned on the light mode menu
will be displayed. The current light mode in use will be
shown. Use the

(

) or

(

) button to

step through the five colour modes:

(1) White

[WHTE]

(2) User Colour [U.CLR]
(3) Fade Effect

[FADE]

(4) Step Effect

[STEP]

(5) Party Effect [PRTY]

Press to activate the light speed [L.SPD] or user
colour [CL:xx] adjustment screens. If FADE / STEP or
PARTY effect modes are selected the current light
speed [L.SPD] will be displayed. If the user colour
[U.CLR] light mode is selected the current colour
number will be displayed (refer below).

Press the

(

) or

(

) button to adjust

the light effect transition speed OR select from 30
colour choices. Press

(

) to confirm selection

or wait for the 10 second idle menu timeout where the
screen steps to the light brightness [L.BRT] screen.

When the [L.BRT] adjustment screen is displayed
press the

(

) or

(

) button to adjust

the light brightness.

Note: If White [WHTE] colour mode is selected the Light
Speed/Colour button has NO function.

ERROR CODES / DIAGNOSTICS

Note: most error conditions require mains power to be turned
and back

before the error is cleared.

Check the

"Heater" sensor lead is plugged firmly into the spa control.

Press

Pump A button to retry water prime. Check spa water level, clean
and soak filters, bleed potential air locks from pipework.

Check spa water level, clean & soak filters, check

all shut-off valves are open, bleed potential air locks from pipework.

Remove spa cover & allow

spa to cool. Check daily filtration time & reduce setting if required.

Turn mains power OFF and unplug and

reconnect "Heater" sensor lead from spa control.

Contact your local dealer. Disconnect "In Pool Sensor" lead

from spa control to continue spa operation.

Reset mains power. Contact your local dealer if problem persists.

OFF

ON

ER2 - HEATER PLUG:

ER3 - WATER PRIME:

ER4 - THERMAL TRIP:

ER5 - POOL TOO HOT:

ER6 - HEATER SENSOR:

ER7 - IN POOL SENSOR:

ER8 - CTRL FAULT:

Heater sensor cable fault.

Heater tube failed to fill with water.

Low or NO water flow over element whilst

heating has activated thermal cut-out device on heater. Turn mains
power OFF and wait 20~30 minutes for heater to cool and thermal
cut-out to reset.

Temperature sensor has reported a

temperature reading in excess of 45 C.

Communication between spa control

and heater has been lost.

In Pool Temperature Sensor has

faulted.

An internal controller fault has been detected.

o

PUMP BUTTONS

ON / OFF / LOW / HIGH / AUTO

There are four pump buttons on the right hand side
of the touch pad: Pump A, Pump B, Pump C and
Pump D. The functions of the four buttons change
depending on pump / controller configuration.
The intention is to make best possible use of these
buttons for all possible configurations. For every press
of a pump button, the display will temporarily show the
selected pump state:
then revert to the default display mode. Possible pump configurations & button sequences are referenced in the
table below (Please tick your spa configuration for ease of future reference).

Notes:

1) If left ON pumps will automatically time-out and turn off 30 minutes after the last sensed button press.
2) In some configurations if heater is ON activating multiple pumps OR turning the blower ON may cause the spa control to

load shed and turn the heater OFF. This is to keep the system within its maximum power load.

RAMPING BLOWER MODE

The spa controller features a ramping blower mode,
were the blower speed gradually fluctuates between
high and low in a ramping manner.

To turn the blower on in ramping mode:

To activate a 20 minute water clean-up cycle:

1) Press the

(

) button

to start

the blower in ramping mode.

2) Press the

(

) button again to turn

the blower OFF.

A sanitise cycle runs the filtration pump and ozone /
uv (if fitted) to filter the spa water to restore and
refresh water quality after use. In addition, at the
start and end of the cycle, the controller will
sequentially run any additional pumps and the
blower (if fitted) for one minute each to purge the
plumbing and clear any unfiltered water trapped in
those lines.

1) Press the

(

) button once after spa

use to activate the water clean [W.CLN] cycle.

BLOWER

BLOWER

ONE-TOUCH SANITISE BUTTON

SANITISE

INVERT BUTTON

twice

The blower will turn

ON and the screen will display [RAMP] to indicate
ramping mode.

Note:

SANITISE

If cycle running, cycle can be cancelled by

pressing the

button again.

Press the

(

) button to flip the screen

180 for ease of viewing when spa in use. The

(

) and

(

) button functions also

change (invert) to match the new display.

INVERT

UP

DOWN

o

AIR BLOWER BUTTON

BLOWER

UP

DOWN

OK

BLOWER

The BLOWER (

) button is used to control the air

blower and allow adjustment of the blower speed.
The last used speed is saved and will be restored the
next time the blower is turned on, for future ON/OFF
use.

1) Press the

(

) button

to turn

the blower ON in variable speed mode.

2) The blower will turn ON (at the last used speed)

and the screen will display the blower speed
[B.SPD] adjustment screen (refer below).

3) Use the

(

) or

(

) buttons to

adjust the blower speed.

4) Press the

(

) button to confirm selection.

5) Press the

(

) button again to turn

the blower OFF.

Note: that when the blower is first turned on it will run

at maximum speed for approx three seconds before
changing to your preset speed; this is normal.

Note: The B.SPD adjustment screen is displayed for 10
seconds when the blower is first turned ON. If no
adjustment is made the blower will run at the last used
speed setting, and the screen will time-out and revert to the
default display mode. If you wish to adjust the blower speed
once the blower has been running for a period of time, the
blower must be turned OFF and back ON again to restore
the B.SPD adjustment screen.

To turn the blower on/off:

once

Note: the bar graph will

change indicating current blower speed.

OK

OK

°C

°F

MODE

SPD

BRT

SPD

OFF

ON

6.SPD

Bargraph indicates blower speed

I

AM

PM

OFF

ON

°C

°F

MODE

SPD

BRT

SAT SUN MON TUE WED THU FRI

L.SPD

AM

PM

OFF

ON

°C

°F

MODE

SPD

BRT

MODE

SPD

BRT

SAT SUN MON TUE WED THU FRI

CL:01

Light speed screen

User colour screen

SPD/

CLR

I

I

I

I

OK

Pump Button

Pump Button

Pump Button

Pump Button

A

B

C

D

Spa Configuration

Button A

Button B

Button C

Button D

No small circ pump

P1, P2 & P3 = 1 speed

Jet pump 1:

On / Off / Auto

Jet pump 2:

On / Off

Jet pump 3:

On / Off

No Function

No small circ pump

P1, P2, P3 & P4 = 1 speed

Jet pump 1:

On / Off / Auto

Jet pump 2:

On / Off

Jet pump 3:

On / Off

Jet pump 4:

On / Off

No small circ pump

P1 = 2 spd, P2 & P3 = 1 spd

Jet pump 1:

Low / Off / Auto

Jet pump 1:

High / Low

Jet pump 2:

On / Off

Jet pump 3:

On / Off

No small circ pump

P1 = 2 speed, P2 = 2 speed

Jet pump 1:

Low / Off / Auto

Jet pump 1:

High / Low

Jet pump 2:

Low / Off

Jet pump 2:

High / Low

Small circ pump fitted

P1, P2 & P3 = 1 speed

Small circ pump:

On / Off / Auto

Jet pump 1:

On / Off

Jet pump 2:

On / Off

Jet pump 3:

On / Off

Small circ pump fitted

P1, P2, P3 & P4 = 1 speed

Jet pump 1:

On / Off

Jet pump 2:

On / Off

Jet pump 3:

On / Off

Jet pump 4:

On / Off

Small circ pump fitted

P1 = 2 spd, P1 = 1 spd

Small circ pump:

On / Off / Auto

Jet pump 1:

Low / Off

Jet pump 1:

High / Low

Jet pump 2:

On / Off

Small circ pump fitted

P1 = 2 spd, P2 & P3 = 1 spd

Small circ pump:

On / Off / Auto

Jet pump 1:

Low / High / Off

Jet pump 2:

On / Off

Jet pump 3:

On / Off

Small circ pump fitted

P1 = 2 speed, P2 = 2 speed

Small circ pump:

On / Off / Auto

Jet pump 1:

Low / High / Off

Jet pump 2:

Low / High / Off

No Function