background image

 

Contents 

Quick using ....................................................................................................... 3

 

Installation attentions ........................................................................................ 3

 

1.

 

Summary ......................................................................................................... 4

 

2.

 

Main functions ................................................................................................ 4

 

3.Specs. .................................................................................................................. 4

 

4. Installation instructions ..................................................................................... 5

 

5.

 

Wires connection ............................................................................................ 6

 

6.

 

Function setting ............................................................................................... 6

 

6.1 Initialization .................................................................................................... 6

 

6.2 Change Password ............................................................................................ 7

 

6.3Authorization .................................................................................................... 7

 

6.4

 

Set up monitor central number ..................................................................... 7

 

6.4

 

Single Tracking ............................................................................................ 8

 

6.5

 

Continuous Tracking Automatically ............................................................ 8

 

6.6

 

Cell ID Tracking .......................................................................................... 8

 

6.7

 

Data logging (optional) ................................................................................ 9

 

6.8

 

Alarms .......................................................................................................... 9

 

6.8.1

 

Power off alarm ......................................................................................... 9

 

6.8.2

 

Geo-fence alarm ........................................................................................ 9

 

6.8.3

 

Overspeed alarm ...................................................................................... 10

 

6.8.4

 

ACC working alarm ................................................................................ 10

 

6.8.5

 

Vibration alarm ....................................................................................... 11

 

6.9

 

Set all alarm mode ...................................................................................... 11

 

6.10

 

Cut off the Oil and Power System .......................................................... 11

 

6.11

 

Resume the Oil and Power System ......................................................... 11

 

6.12

 

Check the Vehicle State .......................................................................... 11

 

6.13

 

IMEI Checking ........................................................................................ 12

 

6.14

 

Time Setting ............................................................................................ 12

 

6.15

 

GPRS Setting .......................................................................................... 13

 

6.15.1 Set APN .................................................................................................... 13

 

6.15.2 Set IP and Port .......................................................................................... 13

 

7

 

. Faults & the Solutions ................................................................................. 14

 

 
 

 
 
 
 

Summary of Contents for TK06B

Page 1: ...ker This manual shows how to operate the device smoothly and correctly Make sure to read this manual carefully before using this product Please note that specification and information are subject to changes without prior notice in this manual Any change will be integrated in the latest release ...

Page 2: ...inuous Tracking Automatically 8 6 6 Cell ID Tracking 8 6 7 Data logging optional 9 6 8 Alarms 9 6 8 1 Power off alarm 9 6 8 2 Geo fence alarm 9 6 8 3 Overspeed alarm 10 6 8 4 ACC working alarm 10 6 8 5 Vibration alarm 11 6 9 Set all alarm mode 11 6 10 Cut off the Oil and Power System 11 6 11 Resume the Oil and Power System 11 6 12 Check the Vehicle State 11 6 13 IMEI Checking 12 6 14 Time Setting ...

Page 3: ...ith valid Long and lat to show location 4 Track online system need set two SMS as below SMS 1 adminip123456 space 116 205 4 114 space 8169 SMS 2 apn123456 space APN of operator space APN user name space APN password 5 Login platform to track in real time please contact supplier Installation attentions NOTE device front side towards the sky Installation if the windscreen glued by metal thermal insu...

Page 4: ...larm Geo fence alarm GSM blind area storage GPS data optional Connect external relay to control vehicle oil or circuit optional Built in backup battery to realize power failure alarm optional 3 Specs Content Specs Dim 84 mm x47 5 mm x 15 mm Weight 50g Network GSM GPRS GPS Band 850 900 1800 1900 Mhz GPS chip UBLOX 7020 GSM module MT6260A GPS sensitivity 159dBm GPS accuracy 5 10m Time To First Fix C...

Page 5: ...3 Recommended installation place The hidden place in the board below the front windscreen The hidden place around former dashboard nonmetal material for skin The hidden place in the board below the back windscreen Notice If the windscreen glued by metal thermal insulation layer or heating layer it will reduce the GPS receive signal and lead to GPS work disorder then please change the installation ...

Page 6: ...to vehicle power anode 2 Black wire connects to vehicle power cathode 3 Yellow wire connects to oil or circuit control wires 4 Green wire connects to ACC ignition wire 6 Function setting 6 1 Initialization Send SMS begin password to the unit it will reply BEGIN CONFIG OK ...

Page 7: ...ll phone from the device tracker Make sure the new password is in 6 digits or else the tracker cannot recognize the password 6 3Authorization There are 5 numbers to be allowed to authorize in the tracker at most 6 3 1 Authorization Send SMS admin password space cell phone number to set up an authorized number the other central number should be set by the first authorized number if the number is su...

Page 8: ...r it will reply CENTERNUM CONFIG OK 6 4 Single Tracking Make a missed call to device number or Send SMS smslink password to device number it will reply a real time tracking message info as below 6 5 Continuous Tracking Automatically 6 5 1Send SMS command ITV password space moving time interval space static time interval to the tracker device 6 5 2 For example send SMS ITV123456 10 500 it will repo...

Page 9: ...g position and alerts automatically in the SD card on the basis of the pre set condition when GSM signals get back all the event alerts will be auto sent to the authorized numbers or monitoring platform server but the logged tracking data should be loaded to the monitoring platform via SMS command 6 8 Alarms Note All Alarms will be sent to Central Number 6 8 1 Power off alarm Setup Send extpower p...

Page 10: ...i diameter set 1 as out fence alarm type 6 8 2 2Cancel Send SMS nostockade password to deactivate this function 6 8 3 Overspeed alarm Set up Send SMS speed password space 80 to the unit suppose the speed is 80km h and it will reply speed OK When the target moves exceeding 80km h the unit will send SMS speed Geo info to the central number Cancel Send SMS speed password space 0 to deactivate the ove...

Page 11: ...ode Send SMS KC password space 0 to tracker to close the function Send SMS KC password space 1 to tracker to choose alarm by SMS Send SMS KC password space 2 to tracker to choose alarm by calling 6 10 Cut off the Oil and Power System Send SMS command DY password space 1 to the tracker device it will reply DY CONFIG OK to your cell phone from the tracker device and stop your car oil pump or elec as...

Page 12: ...ate 1 means activate GF 500 1 0 Geo fence function 500meters 0 1 represent enter fence alarm 0 0 close alarm 1 0 out fence alarm 0 1enter fence alarm Vib vibration level 6 13 IMEI Checking 1 Send SMS command getimei password to the unit E g Send SMS command getimei123456 to the tracker device an IMEI number in 15 digits will reply to your cell phone 2 Send SMS command setimei password space 15 dig...

Page 13: ...lease inquire with your local GPRS network operator 2 Send SMS APN password space local APN space APN name space APN password via a cell phone and if succeeded the tracker will return the message APN OK 3 E g Send SMS command APN123456 CMNET If succeeded it will reply SMS APN OK Notes CMNET is the APN of one of china GPRS Network Operator China mobile it has no APN name and Password 6 15 2 Set IP ...

Page 14: ... if working outside not in room install place has no metal cover Three light turn off Lights will enter sleep after stable lighting on 5 minutes and not effect GPS working when calling device again will wake up lights Can t track online Send SMS TCP check IP port is correct or not GPS located show A V means GPS not located Device has no reply Check if already existing admin number SIM card has bal...

Reviews: