General Information

This manual has been constructed to offer the adequate information on the installation, 
operation and maintenance of our spa pool pumps. We suggest you read it thoroughly for 
correct installation and optimum performance of the pump. 

These are single-stage centrifugal pumps designed to operate with hydro-massage 
equipment on spa pools. They should not be used for any other purpose without first 
consulting your SpaNET dealer or Spa Net Customer Service. The pumps are designed to 

o

operate with clean water at a maximum water temperature of 50 C. 

Installation Location

Ÿ

The pump should be located as close to the water as practical keeping the suction pipe 
of the pump as short as possible.

Ÿ

The pump should be installed on a level firm base in a well drained position, high 
enough to prevent any flooding and be fixed to the base by screws or nuts.

Ÿ

It is the installer’s responsibility to position the pump so that the ratings label can be 
easily read for service, and in a location where water will not drip onto the motor. 

Ÿ

The pump will get hot during operation, to ensure sufficient cooling the minimum 
distance between the motor of the pump and any surrounding structure should not be 
less than 30mm. 

Pipe Connection

Ÿ

The suction pipes should have a diameter equal to or larger than that of the discharge 
pipes, to avoid loss of head and improve pump efficiency.

Ÿ

Two suction inlets must be provided into each pump to avoid suction entrapment. 

Ÿ

Suction & discharge pipes should have a gentle slope of at least 2% to assist purging air. 

Suction Pipe with two inlets

Installation Diagram

Minimum water level for pump operation 

Discharge Pipe

Isolation Valves

Summary of Contents for SMARTFLO SC05

Page 1: ...roduct Failure to follow warning notices and instructions may result in property damage serious bodily injury or death This product must be installed and serviced by a person who is knowledgeable and qualified in pool or spa plumbing and equipment by the jurisdiction in which the product will be installed ...

Page 2: ...ual operating current not exceeding 30mA Ÿ Refer to AS3000 wiring rules Aust NZ and IEC60364 Part 7 Europe or equivalent for guidance with compliance to the wiring codes for wet area and equipotential bonding Ÿ If the supply cord is damaged it must be replaced by the manufacturer its service agent licensed electrician or similarly qualified persons in order to avoid a hazard Ÿ No part of this appli...

Page 3: ...lled on a level firm base in a well drained position high enough to prevent any flooding and be fixed to the base by screws or nuts Ÿ It is the installer s responsibility to position the pump so that the ratings label can be easily read for service and in a location where water will not drip onto the motor Ÿ The pump will get hot during operation to ensure sufficient cooling the minimum distance betwee...

Page 4: ...ng 30mA Ÿ All SmartFLO pump motors have built in thermal protection Ÿ Wires serving as equipotentional bonding conductors shall have a cross sectional area 2 2 between 2 5mm and 6mm and be equipped with suitable terminal receptacles Ÿ Extension power cords are unsafe around spas and pools and should not be used Steps prior to starting pump Before attempting to use the pump you must confirm that Ÿ T...

Page 5: ... with balanced spa water with a pH level of between 7 2 7 8 pH and is to be regularly treated with a sanitising agent with a level not exceeding 3PPM Please visit your local pool and spa shop for regular water tests and for further guidance regarding water chemistry NOTE Do not add raw undiluted chemicals directly to the spa filter area or near the pump suction drains Adding undiluted chemicals may...

Page 6: ...p switches are set correctly and check controller touch pad to confirm pump is active Ÿ Low voltage check there is proper voltage applied to the pump and avoid using extension cables Ÿ Blockage in pipe work or pump wet end in preventing the pump from rotating inspect for foreign debris and remove where required Ÿ Motor has overheated and thermal cut out has activated the pump motor has built in the...

Page 7: ...SB15 105 160 226 266 120 100 351 5 430 10 9 SB20 105 160 226 266 120 100 351 5 430 12 7 SB25 105 160 226 266 120 100 351 5 430 14 1 SB30 105 160 226 266 120 100 351 5 466 15 2 SB15 2S 105 160 226 266 120 100 351 5 480 14 1 SB20 2S 105 160 226 266 120 100 351 5 480 15 0 SB25 2S 105 160 226 266 120 100 351 5 480 17 2 SB30 2S 105 160 226 266 120 100 351 5 480 18 2 SB30 3P 105 160 226 266 120 100 351 ...

Page 8: ... 2 5 low speed 0 45 0 6 high speed 2 1 3 0 SB30 3P 760 15 2 1 3 0 Power MODEL Qmax L min Hmax m SB15 2S 560 13 SB30 2S 790 15 SB20 2S 690 14 SB25 2S 760 15 Pump Specifications Contact Details Spa Net Pty Ltd 4 103 Railway Road North Mulgrave NSW 2756 Australia Phone 61 2 4587 7766 Fax 61 2 4587 8766 www spanet com au Technical Support Service service spanet com au Accounts Department accounts spane...

Reviews: