3- Delivery’s control
At the delivery time, check the condition of packing; in case of
damages, have reservation about them to the carrier, before 48
hours and by registered letter with acknowledged receipt.
Before any manipulation, check the complete state of the machine.
4
-
Technical description
Characteristics:
MODEL
SHP-60P
SHP-80P
SHP-100P
SHP-120P
SHP-140P
SHP-170P
SHP-190P
Power supply
230V~,
50Hz
230V~,
50Hz
230V~,
50Hz
230V~,
50Hz
230V~,
50Hz
230V~,
50Hz
230V~,
50Hz
Heating
consumption
power * (kW)
1.1
1.5
1.9
2.2
2.6
3.1
3.4
Heating restored
power *(kW)
6
8.3
10
12
14
17
19.5
Heating nominal
intensity *(A)
5.3
7.2
9.0
10.8
12.8
15
19
Cooling
absorptive power
* (kW)
1.2
1.6
2.0
2.3
2.7
3.2
3.5
Cooling restored
power *(kW)
4.3
5.8
7.2
8.1
9.7
11.5
14.5
Cooling nominal
intensity *(A)
5.8
7.8
9.8
11.5
13.6
16
20.3
Air flow (m
3
/H)
1700
1700
2000
2000
3200
4000
4000
Noise level
(d(B)A)
<48
<49
<50
<51
<52
<53
<54
Refrigerant gas
R410a
R410a
R410a
R410a
R410a
R410a
R410a
Rate of average
filling of gas (g)
620
850
950
1300
1450
1650
2100
Net weight of the
unit (kg)
51
55
60
62
77
97
100
Overall sizes L x
W x H (cm)
99x36x62
99x36x62
99x36x62
99x36x62
112x48x84
112x48x84
112x48x84
* possible variations of value according to climatic conditions
**Heating by max ambient temperature: 27
℃
***Cooling by max ambient temperature: 43
℃
Summary of Contents for SHP-100P