Troubleshooting
Euro Kitchen Appliances Inc. 7272 Buller Ave, Burnaby BC www.KitchenHoods.ca
1. If the range hood or halogen light does not operate •
after installation:
•
Check if the range hood has been plugged in, make
sure that all power has been turned back ON, fused
not blown and all electrical wiring are properly
connected.
Swap out light assembly to working ones to deter-
mine whether it is caused by defective bulbs.
2. The range hood vibrates when the blower is on:
• The range hood might not have been secured
properly on to the wall.
3. The blower or fan seems weak:
• Check that the duct sized used is at least 6” or 3-1/4
x 10”. Range hood WILL NOT function efficiently
with insufficient duct size. For example: 7” duct
over 6” hole and loosely secured.
• Check if duct is clogged or if damper unit (half-
circular flapper) is not installed correctly or
opening properly. A tight mesh on a side wall cap
unit might also cause restriction to the air flow.
4. The lights work but the blower is not spinning at all, •
is stuck or is rattling.
The blower might be jammed or scraping the bot-
tom due to shipping damage. Please contact us
immediately.
5. The hood is not venting out properly:
• Make sure the distance between the stove top and
the bottom of the hood is within* 27” and 30” in
distance. *
Due to different ceiling height
configurations, recommended height may not be
applicable.
• Reduce the number of elbows and length of duct
work. Check if all joints are properly connected,
sealed, and taped.
• Make sure the power is on high speed for heavy
cooking.
NOTE:
For all other inquiries, please contact us at
or call 1-800-315-0359