Once you have set all your ONs and OFFs you can review all the programs you have set by  
 

Pressing 

 (SET will be displayed) then, 

 then, 

 then, 

 Fnc will be displayed 

then press 

. AN-1 will be displayed, press 

 and AUTO will be displayed. Press 

Then using the 

 key you can scroll through all the timer settings that have been set up  

 
and add more if required. 
 

See section 11.2 on page 5 of the manual for more information. 

 
 

4.PAR Used to access all the parameters from Fan set up, Zone Qtys, Burner Qtys 

 

Press 

 (SET will be displayed) then, 

 then, 

 this will display PAR. Press 

 this 

will then display PA. Press 

 Again. This is where you now enter the Password for the unit 

to change the  
 
Parameters, this can be locked by the customer with there own password. Use Installer  
 
Password 95 or Factory Password 59. Please see page 7 of the manual under section 17. 
 

Press the 

 to enter the passcode required then Press 

. You can then use the  

 

to scroll through all the parameters found in section 17 on page 6 of the manual  

 
and section 4.2 on page 2 to find the desired H5 parameter. 
 
When we set these up to send to the customer we will only set the H5, FB and  
 
FBF codes. 
 
 
 
 
The H5 code is the code to set the Operation mode for heating zones, sensor connections  
 
and common AUX fan if fitted. Scroll through the parameters until you come to H5 then Press 

, using 

scroll to the desired operation mode as shown in section 4.2 on page  

 
2 and 3, for example H5=12 is 3xZones made of 1x single stage independent heater each +  
 

Common exhaust fan. Press 

 again, this will take you back to the H5 Display. Press 

. Then reset the unit by pressing and holding the power button 

 until OFF is 

displayed then press the power button 

 to turn the unit back on. 

 
 