WARNING: Due to the continuous length of time the heater might be in operation, a 100 lb. LP gas cylinder may not
be sufficient in size. Manifolding several cylinders together is a practical way of increasing the time of operation of
these heaters. Operation of the heater with insufficient sized cylinders or when the liquid level becomes too low will
result in poor heater performance and can cause sooting. Consult your LP gas dealer for proper sizing of container.
Always turn the gas off at the tank or cylinder when the heater is not in use. When in operation, keep the heater a safe
distance from the LP gas container and combustible materials as indicated on the heater and in the instructions. Fasten
LP cylinders securely so they cannot be knocked over.
8. VENTILATION AND COMBUSTION AIR
This heater requires ventilation in the building to dilute the products of combustion and provide fresh air for
efficient
combustion. The minimum recommended vent flow required is as follows:
RFPA21A:
880 cfm
The combustion air enters through the heater base and must not be restricted. DO NOT block or enclose any part of
the heater base. All ventilation in the building must be at a level above the height of the heater.
9. LIGHTING AND SHUTDOWN INSTRUCTIONS
MODELS WITH IGNITION SUFFIX "-6"
1. Pull lock button and turn valve handle to "Pilot" position; DO NOT pull out valve handle - Push down button
and light pilot. Hold button in firmly for approximately 30 seconds or until pilot remains lighted without
holding button down. If air is in the line, it will take a few minutes for gas to reach the pilot.
2. Turn handle to "ON" position.
3. If heater does not light, shut off gas completely for five minutes
before attempting to relight.
4.
To turn off main burner and pilot gas, pull lock button and turn
handle to "OFF".
CAUTION: DO NOT PULL OUTWARD ON VALVE HANDLE
CAUTION: DO NOT OPERATE MAIN BURNER AT ANY SETTING LESS THAN FULL "ON" POSITION.
SOOTING WILL OCCUR!
Correct
Incorrect