Form 43343110
May 2021
-17-
9.4)
ASSEMBLY OF EXTENSION SECTION
See typical assembly overview (Section 7.1) for typical complete assembly. Assemble additional extension
sections as required for all systems. (See Section 7.0) for typical layout details.
Join the tube sections together and secure with tube couplings as described below:
The following coupling tightening instructions MUST be followed properly
to ensure the integrity of the tube connections. Two #10 self-drilling
screws MUST be installed at every coupling as shown in the instructions
below. Failure to do so may result in serious injury or property damage.
1.
Place the compression coupling over the end of the tube.
2.
Use the small hole at the centerline of the coupling to check that the coupling is inserted correctly.
3.
Partially tighten the bolt nearest the end of the tube (approximately half closed).
Summary of Contents for PCA-SS 100
Page 13: ...Form 43343110 12 May 2021 7 1 DIMENSIONS STRAIGHT CONFIGURATION 48 HANGING CENTERS...
Page 14: ...Form 43343110 May 2021 13 7 2 HEATER ASSEMBLY JOINING OF TUBE SECTIONS...
Page 21: ...Form 43343110 20 May 2021...
Page 48: ...Form 43343110 May 2021 47 19 0 TROUBLESHOOTING GUIDE SINGLE STAGE N5 L5...
Page 49: ...Form 43343110 48 May 2021 TROUBLESHOOTING GUIDE SINGLE STAGE CONTINUED...
Page 50: ...Form 43343110 May 2021 49 TROUBLESHOOTING GUIDE SINGLE STAGE CONTINUED...
Page 51: ...Form 43343110 50 May 2021 19 1 TROUBLESHOOTING GUIDE TWO STAGE N7 L7...
Page 52: ...Form 43343110 May 2021 51 TROUBLESHOOTING GUIDE TWO STAGE CONTINUED...
Page 53: ...Form 43343110 52 May 2021 TROUBLESHOOTING GUIDE TWO STAGE CONTINUED...