START UP PREPARATIONS
Before performing the operations in this section, make sure you have read and
understood all of the previous instructions set forth in this manual. Make sure the spa has
been installed correctly, including electrical wiring connections as specified in the
previous section.
Things to check before turning on the power to the spa:
1.
Spa’s water is at the correct level.
2.
Pump is primed (call spa dealer for priming instructions.)
3.
Ensure all valves are opened.
4.
Turn circuit breaker on.
5.
Press the button labeled “Jets” on the control panel. If the pump is well primed, you
should be able to feel a steady flow of water. If not repeat steps 2-5.
Note:
Do not turn breaker on for the spa when there is no water in the tub.
INITIAL START UP
On start up place the selector switch to
Time Filtration & Automatic Heat
Mode
(option 1,)
Timer Mode
(option 2) &
Thermostat Mode
(option 3). This will
allow the spa to heat to the set temperature. The low speed pump and the ozonator
(optional) will automatically turn on with the heater.
If the system is left in
Time Filtration & Heat Mode
(option 1) or
Time Clock
Mode
(option 3) the spa will heat only during the filtration cycle(s) that are set on the
time clock. If the cycle(s) are too short in duration, the spa may not have enough time to
heat up to heat up to temperature before the cycle ends.
INITIAL START UP