background image

 

Chart 2 

 

Press the “M” button and hold for approx.3sec to leap to next Data Set. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The UNIT Button Function Declaration: 

 

The functions are separated into two group of measurements.  

One is the rate measurement which is shown on the left side of the following flow chart. 

The other is the revolution and length measurements which are shown on the right side of the 

following flow chart. 

The user can press the “UNIT” button once to change from RPM, rPm...., to the next sequentially. 

Press the “UNIT” button and hold for approx.3sec to leap to next group, can select to REV test 

 

 

 

 

 

Data 

 

Max Data0 

 

Min Data0 

 

Avg Data0 

 

Data 

 

Max Data1 

 

Min Data1 

 

Avg Data1 

 

Data 

 

Max Data2 

 

Min Data2 

 

Avg Data2 

 

Data 

 

Max Data9 

 

Min Data9 

 

Avg Data9 

 

Summary of Contents for SP62030

Page 1: ...D ATTACH RECEIPT TO MANUAL FOR FUTURE REFERENCE NOTE Proof of purchase must be retained by the customer as it will be required in the event of a claim under warranty AFTER SALES SUPPORT AUSTRALIA Visi...

Page 2: ...of data includes a MAX measurement a MIN measurement an AVG measurement Auto back light Ultra low power consumption in shutdown mode 2 Safety Information Read the following safety information careful...

Page 3: ...on Range of Non Contact 7 0 99 999 RPM Total number of revolutions 1 99999 REV Accuracy 7 0 5999 9 RPM 0 01 and 1digit 5999 9 99999RPM 0 05 and 1digit Detection Laser Diode Resolution 7 0 9999 9RPM 0...

Page 4: ...UNIT button E Measure button F Memory button G Display window H Sensor of auto back light I Battery cover 4 3 Display a Scan Press the measuring button the data will update and SCAN will show b Hold...

Page 5: ...l the stored data from memory Use the MEM button to scroll and view the stored data point 1 See the flow chart 1 for a brief presentation of how to recall the stored data sequentially 2 See flow chart...

Page 6: ...flow chart The other is the revolution and length measurements which are shown on the right side of the following flow chart The user can press the UNIT button once to change from RPM rPm to the next...

Page 7: ...ements Y M Contact Yard per minute measurements F M Contact Feet per minute measurements REV Revolution measurements M Length Using the master 10cm circumference wheel measurements in the unit of metr...

Page 8: ...remaining debris away with a camel s hair brush Carefully wipe the surface with a cotton swab moistened with water NOTE DO NOT use solvents to clean the lens Clean the housing Use soap and water on a...

Page 9: ...or normal wear and tear 1 2 Has been used in a manner other than for which it was originally designed 1 3 Has been tampered with or is otherwise than as supplied by SP Tools 1 4 Where any damage malfu...