9
6. Once the vehicle has started
turn the power button to the “OFF” position, remove
jumper cable from Li
+
Power Bank and disconnect RED and BLACK clamps from the
vehicle battery terminals.
7.
Note:
Once the engine is running, be sure to allow enough time for the vehicles
alternator to restore charge to the vehicles battery before turning it off again.
7. Troubleshooting
FAULT
CAUSE
REMEDY
LED display shows a solid
red “8” accompanied by
long continuous beeping.
Reverse polarity
connection.
Jumper leads are
connected to the wrong
terminals on the vehicles
battery.
Remove jumper leads from
battery and connect them to
the correct terminals as per
instructions on page 8 of
this owner’s manual.
LED display shows solid red
“8” accompanied by short
continuous beeping.
Short circuit protection.
There is a short circuit
between the jumper leads.
Remove clamps from
vehicle battery, check for
short circuits. If short circuit
is caused by damage to the
jumper leads, discontinue
use until replacement leads
are available.
LED display shows solid red
“8” accompanied by short
fast continuous beeping.
Over-heat protection.
The Li
+
Power Bank has
become too hot.
Remove clamps from
vehicle battery, Allow the
unit to cool sufficiently
before next use.
LED display shows solid red
“8” accompanied by 2 short
fast beeps.
Over-discharging
protection.
The Li
+
Power Bank is low
on charge.
Recharge the Li
+
Cobalt
Power Bank.
LED display flashing
Green/Red “8”.
The Li
+
Power Bank is
searching for a connection.
Ensure battery terminals
are clean (free from
corrosion) and re-check
connections.
All error codes with a solid red “8” being displayed can be reset by turning the Li
+