- 9 -

   

Flush-Mounted Series

Flush-Mount Backlight Multi-Function Controller / Flush Mount Illuminated Access Reader 

Function Default Value

AR-888-H

20    DDD

Function

Selection

Value Application

Default Value

Time Attendance
Auto Relock
Auto Open
Exit by RTE Button
Master Controller of Network
Entrance/Exit 
Anti-pass-back 

0: Yes

0: Disable

0: Disable

   

0: Disable

0: Slave

0: Exit

0: Disable

Networking
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking
Networking
Networking

001
002
004
016
032
064
128

   1: No
   1: Enable
   1: Enable

1: Enable

   1: Mater
   1: Entrance
   1: Enable

24    DDD

Function

Selection

Value Application

Default Value

Auto Open without Presenting in Auto-open Time Zone
Alarm Output/ Lift Control
Stop Alarm by pressing RTE Button or Closing the Door
Doorbell

0: Disable

0: Alarm Output

   

0: None 

0: Disable

Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone

001
002
064
128

     1: Enable
     1: Lift Control

※ 

1: Yes

     1: Enable

28    DDD

Function

Selection

Value Application

Default Value

Double Door Control
Force Open Alarm Output

0: Disable

   

0: Disable

Networking/Standalone
Networking/Standalone

064

128

   1: Enable

1: Enable

Select the desired function, Weighted Value = 

Selection Index (0 or 1) x Value.

[e.g.] DDD (total weighted value of all functions): 

Enable "Auto Open" + "Exit by RTE Button" + "Anti-

pass-back"=1*004 + 1*016 + 1*128=148; As a result 

of that, the command will be 20    148    .

34    DDD

Function

Selection

Value Application

Default Value

Enable the RF after door sensor closed to GND
Invalid card to activate alarm relay

Turn off all sounds of beeper

Mute the sounds of egress button (RTE) 
Reserved
Keep beeing while arming is enabled
Door relay connected to AR-721RB (suited to models without relay built-in)
Arm relay connected to AR-721RB (suited to models with relay built-in)

0: Deactivate

0: Deactivate

0: Deactivate

0: Deactivate

0: Deactivate

0: Deactivate

0: Deactivate

0: Deactivate

Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone

001
002
003
004
016
032
064
128

1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate
1: Activate

Enable: 

Enter program mode

 → 

After door open : 

The normal procedure to open door

 → 

Input 4-digit arming PWD

 

Disable: 

Enter program mode

 →

Do not open the door

      →

Input 4-digit arming PWD

 → 

Present a valid card

Enable/Disable Arming status

 

(for M4/M8)

:

More Details:

SOYAL Security Related Function

※ 

[The normal procedure to open door] can refer to [Access Mode].

※  

Read the [Command List-Arming /Duress Function Setting] below to modify arming PWD.

※  

M6 is Standalone Mode, the mode is without Arming /Duress Function.

Enter Programming Mode

Without Enter Programming Mode (Standby Mode): Enter Arming Code

 

default value of arming PWD is: 1234

   

   

Factory Reset by its commands

Reset User Data

Reset User Data &Controller Parameter 

(incl. Master Code)

Reset User Data &Controller Parameter 

(incl. Master Code)  & Reset Parameter Setting- SOR

 Enter program mode

 →

29

     

29

  →  

Exit the programming mode   

   

Enter program mode

 →

29

     

20

          

→ 

Exit the programming mode

Enter program mode

 →

29

     

21           

→ 

Exit the programming mode     

 

If forgotten the current Master Code, Reset through software tools is required. Please refer to the FAQ for more detail

How to change or reset different kinds of Controller Settings, including Master Code, Parameter Setting and User Data?

Summary of Contents for AR-888H

Page 1: ...e Application Pin Color Description 3 PIN Connector 1 Black GND 2 White Duress 3 Purple Arming Security trigger signal 888 K U 125kHz 13 56MHz Cable CN5 Cable CN4 Wire Application Pin Color 888 H Desc...

Page 2: ...ttach C to B at lower position of B Push C up to make the cogging hooked completely Use the Allen key and screws to assemble the body C onto the mounting plate B Attach the Back Cover D to C Hands off...

Page 3: ...CN1 CN1 CN1 CN5 P T Exit Flush Mounted Series Flush Mount Backlight Multi Function Controller Flush Mount Illuminated Access Reader Request To Exit Request To Exit Request To Exit Electric Bolt AR 12...

Page 4: ...s to 1 3 5 7 floor 21 00001 0 01010101 POWER DC12 24V POWER DC12 24V POWER AC18V AR 821RB AR 821RB Controller Traditional Electronic Door Lock Traditional Electronic Door Lock Controller Controller po...

Page 5: ...ng 17 command to set Arming PWD as 0000 2 Card and PIN 4 digitpublicPIN ArmingPWD 3 Card or PIN 4 digitpublicPIN Duresscode 1 Card only 2 Card and PIN 4 digitPrivatePIN 3 Card or PIN 4 digit Private P...

Page 6: ...g Add User Address 00100 Enter program mode 11 00100 00100 OK e g Add a batch of user with sequential Card Number of user address 12058 until 12559 total 50 tags Enter program mode 11 012058 012599 OK...

Page 7: ...01 and pass code 1234 input 13 00001 1234 M6 Public PIN Card or PIN Enter program mode 15 PPPP Input 4 digit PIN default value 4321 PPPP 0000 cancel the function of simply inputting PIN to get access...

Page 8: ...g door is forced openg door is forced openg In the security management of access control system the controller or reader status is divided into Standby Mode or Disarming Mode and Arming Mode The condi...

Page 9: ...s of egress button RTE Reserved Keep beeing while arming is enabled Door relay connected to AR 721RB suited to models without relay built in Arm relay connected to AR 721RB suited to models with relay...

Page 10: ...d code UUUUU User Address QQQQQ Card quantity 00001 for adding a single card or a batch of random numbering cards N 0 Delete tag N 1 Add tag After enabling Door Open For Any Tag all cards in same freq...

Page 11: ...s function ex AR 725 H UUUUU User Address S 4 sets of lift control 0 3 FFFFFFFF 8 assigned floor F 0 Disable 1 Enable NNN site number TTT relay time 000 600 1 600 sec UUUUU User Address FF Floor 01 32...

Reviews: