Soyal AR-829E Manual Download Page 4

V091119

   

   

M1

Board

Horn

M2

1
2
3
4
5
6
7
8

N.C.

N.O.

COM

CTL

12V

ALM

12V

GND

GND

P1

LCD Access Controller

F. Lift control

G. Alarm Clock (for Factory)

Connect with 

AR-401RO16B

 to control which floors the user will be able to access.

Output to 

M1

 and 

M2

Mike device

Mike device

Music Box

Music Box

Mike's sound wire

Mike's sound wire

DC 12V Relay Board

Access programming mode

 →     

Tools

 →    

 Terminal Port

 → 

1

AR-401RO16

5

4

Setting Lift control

Hardware installation

Software Setting 

Access programming mode

 →     

User Setting

 →    

 Single Floor

 →

Input 5-digit user address

 → 

Input single floor number: 1~64

2

4

Single floor

Access programming mode

 →     

User Setting

 →    

 Multi Floor

 → 

Input 5-digit user address

 → 

Select range: 1 or 2 or 3 or 4

 → 

Input 16 digits 

multi floors number [0:disable, 1: enable]

[i.e.] Set NO. 114, can use it with the 8 F and 16F:

       

Access programming mode

 →     

User Setting

 →    

 Multi Floor

 → 

114

     

 

→ 

1     

 

→ 

0000000100000001

           

2

2

5

5

Multi floors

Set Floor/ Stop

1

0

17

0

33

0

49

0

9

0

25

0

41

0

57

0

1

2

3

4

3

0

19

0

35

0

51

0

11

0

27

0

43

0

59

0

2

0

18

0

34

0

50

0

10

0

26

0

42

0

58

0

4

0

20

0

36

0

52

0

12

0

28

0

44

0

60

0

5

0

21

0

37

0

53

0

13

0

29

0

45

0

61

0

6

0

22

0

38

0

54

0

14

0

30

0

46

0

62

0

7

0

23

0

39

0

55

0

15

0

31

0

47

0

63

0

8

1

24

0

40

0

56

0

16

1

32

0

48

0

64

0

The AR-821E/AR-829E controller can support up to 12 sets of ring per day
1. Click [82X] to [829E/821E Parameter Setting]
2. Select target node of AR-829E
3. Click [Read From Controller] to read the parameters of target 829E
4. Press [Daily Time Schedule] to start weekdays and timing settings
5. Select [SUN to MON]
6. Set up [Event] for timing to ring the bell and set up [Sec.] for activating time 

of ring. (Range: 01~44 seconds; if you set 0 second there will not be action.)

7. Click [Yes] after setting
8. Click [Write To Controller] to end Setting

7

8

6

3

4

5

2

1

Manu Tree

5. Tools

1. Language
2. Master Code
3. Master Range
4. Terminal Port
5. AR401RO16 Node
6. Open Time Zone
7. Informations
8. Clock Setting

6. Quit

7. Quit & Arming

4. Parameters[2]

1. Auto Relock
2. Egress(R.T.E)
3. Attendance
4. Master Node
5. Force Open
6. Close & Stop
7. Anti-pass-back
8. Duress Code

3. Parameters[1]

1. Node ID
2. Auto open Zone
3. Door Relay Tm
4. Door Close Tm
5. Alarm Relay Tm
6. Alarm Delay Tm
7. Arming Delay Tm
8. Arming PWD

2. User Setting

1. Password
2. Access Mode
3. Extend Options
4. Single Floor
5. Multi Floor

1. Add/ Delete

1. Add > Card ID
2. Add > RF Learn
3. Suspend > Address
4. Suspend > ID #
5. Delete > Address
6. Delete > ID #
7. Recover > Address
8. Recover > ID #
9. Antipass Group

Controller 

POWER

12VDC

Reviews: