E. PIN Code
F. Arming Password
G. Duress Code
Access programming mode
→
User Setting
→
Password
→
Input 5-digit user address
→
Input 4-digit PIN (0001~9999)
→
Succeeded
Or via 701Client set it on Users screen
2
1
Access programming mode
→
Parameters[1]
→
Arming PWD
→
Input 4-digit PIN (0001~9999; Default: 1234)
→
Succeeded
Or via 701Server and set it on AR-829E screen
3
8
Access programming mode
→
Parameters[2]
→
Duress Code
→
4 sets (select one)
→
Input 4-digit PIN (0001~9999)
→
Succeeded
Or via 701Server to set it on AR-829E screen
※
Duress Code is only available in networking mode. It will substitute a personal pin code and send the message of Duress to computer as a warning
signal.
4
8
H. Setting up the alarm
Enable/Disable the arming status:
Standby Mode
Access Programming mode
Card only
Card or PIN
Card and PIN
Open the door
Present the tag to reader
→
Input
4 digits arming PWD
→
Input user address
→
Input 4
digits individual PWD
→ →
Input 4 digits arming PWD
→
Present the tag to reader
→
Input
4 digits individual PWD
→ →
Input 4 digits arming PWD
→
Enable:
Access programming mode
→
Quit & Arming
7
Disable:
Access programming mode
→
Quit
6
No open the door
→
Input 4 digits arming PWD
→
Present the tag to reader
Conditions:
1. Arming enabled
2.Alarm system connected
Programming
B. Entering and Exiting Programming Mode
C. Initial setup
Exiting
Press the repeatedly
→
Quit
6
Changing the Master Code
Access programming mode
→
Tools
→
Master Code
→
Input the 6-digit new master code
→
Succeeded
5
2
Node ID of Reader Setting
Access programming mode
→
Parameters[1]
→
Node ID
→
Input New Node ID:1~254
(default value: 001)
→
Input: 1~4 to Show Card ID
mode
(1.WG, 2.ABA10, 3.ABA8, 4.HEX)
→
Succeeded
3
1
Language Setting
Access programming mode
→
Tools
→
Language
→
EN
→
Succeeded
→
Initial system...
5
1
1
A. Keyboard Lock/ Unlock
Lock/ Unlock
Press and , and at the same time to lock keyboard. Press once to unlock.
Application:
1. Door open too long
: Door is open longer than door relay time plus door close time.
2. Force open
(Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal
: When power is off and then on, reader on arming before power off.
Access mode Card and Pin or Card or Pin or Card only for the model AR-721K
Access mode Card only for the model AR-721U, AR-737H/U (WG mode) and AR-661U
J. Anti-pass-back
Device enable
Access programming mode
→
Parameters[2]
→
Anti-pass-back
→
must select [1: Yes]
4
7
Card user enable
Access programming mode
→
Add/ Delete
→
Antipass Group
→
Input 5-digit starting user address
→
Input 5-digit ending user
address
→
must select [1: Yes]
1
9
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456. If already changed the Master Code= 876112, input
876112
→
Access programming mode
P.S.If entering no instruction within
30 sec.
, it will automatically leave the programming mode.
Access programming mode
→
User Setting
→
Access Mode
→
1: Card; 2: or PIN; 3: & PIN; 4: Pause;
2
2
Setting up the access mode