Soyal AR-723 Quick Start Manual Download Page 3

SOYAL

®

AR-723 (H)

V200620

Access Controller

   

   

   

   

Enable: 

Access programming mode

 → 

Disable: 

Access programming mode

 → 

Factory Reset by its commands

When the device is stand-alone (not networking)

Access programming mode

 → 

20

     

016

      → 

24

     

064

      → 

26

     

00000

     

01023

     

1

      → 

28

     

000

      → 

29

     

29

Note: After the Master Code is changed, factory reset doesn’t restore the Master Code back to 123456.

Enable/Disable Arming status (for M4/M8; Factory default armingcode is: 1234) :

Standby Mode

Enter Program Mode

After door open
The normal procedure to open door

 → 

Input 4 digit arming code

 →

Do not open the door

     → 

Input 4 digit arming code

 → 

Present valid card

※ 

[The normal procedure to open door] can refer to [Access Mode].

D. Setting Up the Arming 

[Only for connect to external K-series reader]

Alarm conditions:

1. Arming is enabled
2.Alarm system connected

Application:
1. Door open too long

: Door is open longer than door relay time plus door close time.

2. Force open

 (Opened without a valid user card): Access by force or illegal procedure.

3. Door position abnormal

: Arming is enabled and the power is suddenly off then on.

Function Default Value

Mode4 / Mode6 / Mode8

※ 

Mode 6,

 the number of users up to 65535, since it reads 

CARD CODE

(5 digits) only, unlike that Mode4/Mode8 read 

SITE CODE

 and 

CARD CODE

(10 digits).

If Access Mode setting to use the PIN, 

it

 

need to external the K-series Readers.

Selection= 0(none value)/ 1(1 x each value) 

[e.g.] DDD value of Enable “Auto Open” + ”Exit by Push ”Anti-pass-back”  

         =(0x1)+(0x2)+(1X4)+(1x16)+(0x32)+(0x64)+(1x128)=148 ; As a result of that, the command will be 20     148    .

20    DDD

Default Value

Function

Selection

Value Application

Attendance

0: Yes

   1: No

001

Networking

Auto Re-lock

0: Disable

   1: Enable

002

Networking/Stand-Alone

Auto Open

0: Disable

   1: Enable

004

Networking/Stand-Alone

Door open button input

   

0: Disable

1: Enable

016

Networking/Stand-Alone

Master Controller of Network

0: Slave

   1: Mater

032

Networking

24    DDD

Default Value

Function

Selection

Value Application

Auto-open door without cards at auto open zone

0: Disable

     1: Enable

001

Networking/Stand-Alone

Alarm Output/ Lift Control

0: Alarm Output

     1: Lift Control

002

Networking/Stand-Alone

Stop Alarm by door close or by push button

   

0: None 

※ 

1: Yes

064

Networking/Stand-Alone

28    DDD

Default Value

Function

Selection

Value Application

Dual Door Control

0: Disable

1: Enable

064

Networking/Stand-Alone

Force Open  Alarm Output

0: Disable

1: Enable

128

Networking/Stand-Alone

Mode Networking/

Stand-Alone

User 

Capacity

Access Mode

Auto-show 

Duty time

Event log 

Capacity

120 

Holidays

Anti 

force

Time 

Zone

Lift 

Control

Anti-pass-

back

M4

Networking/

Stand-Alone

1,024

1.Card only

2.Card and PIN 

(4-digit PIN)

3.Card or User address 

(5-digit) 

+ Individual PIN 

(4-digit 

individual PIN) 

+

Yes

1,200

Yes

Yes

No

32

Yes

M6 Stand-Alone

65,535

1.Card only

2.Card and PIN

 (4-digit public PIN= Arming PWD)

3.Card or PIN 

(4-digit public PIN= Duress code)

No

No

No

No

No

No

No

M8

Networking/

Stand-Alone

1,024

1.Card only

2.Card and PIN

 (4-digit individual PIN)

3.Card or PIN 

(4-digit individual PIN)

Yes

1,200

Yes

Yes

No

32

Yes

Reviews: