V200620
323DMaster
2
1
AR-723 (H)
321CM
A+
B-
7
8
RS485
AR-723 (H)
Access Controller
About Master Card
Enter the program mode
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input
876112
→
program mode accessed
Exit the program mode
Input
Operation process
M4/M8: Individual pass code
Card or PIN:
Access programming mode
→
12 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 ]
Card and PIN:
Access programming mode
→
13 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 13 00001 1234 ]
M6: Public pass word
Card or PIN:
Access programming mode
→
15 PPPP [Input 4-digit pass code, default value: 4321]
Card and PIN:
Access programming mode
→
17 PPPP [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]
B. Set up the password
[Only for connect to external K-series reader]
Master Code modification
Access programming mode
→
09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] Set the Master code to be 876112, input
123456
→
09 876112876112
A. Enter/ Exit Program Mode
Adding Tag
Present Master Card
Deleting All Tags
Present Master Card
P.S. Once MASTER CARD is presented after one
warning beep, all card data will be cleared.
After 3 short beeps
[Access programming mode]
After 3 short beeps
[Access programming mode]
Present the new card or cards
one by one till finished the adding.
1 long warning beep after 2sec.
Present Master Card
[Exit programming mode]
5 short beeps after 5sec: cards cleared
1.
1.
2.
2.
3.
3.
4.
4.
MASTER CARD Setting for Stand-Alone
Use the MASTER CARD software
Input the MASTER CARD number, and press [Write].
Cut off and then transmit the power, the master card number will be activated.
Present the card, and the reader will flash green light 3 times and sound 3 beeps. Then the card becomes MASTER CARD and accesses programming
mode.If MASTER CARD is presented again, it will exit programming mode.
Converter
USB
C. Lift control
Enable
Access programming mode
→
24 002 [002= enable lift control]
Connect with
AR-401RO16B
to control floors which the user will be able to access.
[e.g.] User address NO. 168, only to the 6th and the 20th floor:
Access programming mode
→
21 00168 0 00100000
→
21 00168 2 00001000
Multi floors
Access programming mode
→
21 UUUUU S FFFFFFFF
[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable)
Single floor
[e.g.] User address NO. 45, allow to access the 24th floor:
27 00045 24
Access programming mode
→
27 UUUUU FF
UUUU=User Address FF=Floor number (01~32 floor)
Set
Floor/ Stop
F
8
16
24
32
0
1
2
3
F
6
14
22
30
F
7
15
23
31
F
5
13
21
29
F
4
12
20
28
F
3
11
19
27
F
2
10
18
26
F
1
9
17
25