- 4 -

Function Default Value

20    DDD

Default Value

Function

Selection

Value Application

Attendance

0: Yes

   1: No

001

Networking

Auto Re-lock

0: Disable

   1: Enable

002

Networking/Stand-Alone

Auto Open

0: Disable

   1: Enable

004

Networking/Stand-Alone

Door open button input

   

0: Disable

1: Enable

016

Networking/Stand-Alone

Master Controller of Network

0: Slave

   1: Mater

032

Networking

24    DDD

Default Value

Function

Selection

Value Application

Auto-open door without cards at auto open zone

0: Disable

     1: Enable

001

Networking/Stand-Alone

Alarm Output/ Lift Control

0: Alarm Output

     1: Lift Control

002

Networking/Stand-Alone

Enable swipe any tags to  release door open

0: Disable

     1: Enable

032

Networking/Stand-Alone

Stop Alarm by door close or by push button

   

0: None 

※ 

1: Yes

064

Networking/Stand-Alone

28    DDD

Default Value

Function

Selection

Value Application

Dual Door Control

0: Disable

1: Enable

064

Networking/Stand-Alone

Force Open  Alarm Output

0: Disable

1: Enable

128

Networking/Stand-Alone

1.

Normal Opening

 

2.

Abnormal Opening

 

Enable: 

Enter program mode

 → 

After door open : 

The normal procedure to open door

 → 

Input 4-digit arming PWD

 

Disable: 

Enter program mode

 →

Do not open the door

      →

Input 4-digit arming PWD

 → 

Present a valid card

Enable/Disable Arming status

 

(for M4/M8)

:

More Details:

SOYAL Security Related Function

Arming Setting and Alarm Trigger Procedure : 

※ 

[The normal procedure to open door] can refer to [Access Mode].

※  

Read the [Command List-Arming /Duress Function Setting] below to modify arming PWD.

※  

M6 is Standalone Mode, the mode is without Arming /Duress Function.

Enter Programming Mode

Without Enter Programming Mode (Standby Mode): Enter Arming Code

 

default value of arming PWD is: 1234

Arming Mode

Disarming Mode

T

riggering Alarm 

Condition:

T

riggering Alarm

 Condition:

VS

abnormal door 

position

door open to

o

long

door is for

ced

openg

door is for

ced

openg

Door Relay TM

Arming Delay TM

Enable Arming

Alarm Relay TM

Door Close TM

Alarm Delay TM

Enable

Arming Status

Alarm Trigger

Door open 

Green Led Flash Quickly

Red Led Flash Quickly

Alarm trigger

Green Led Flash

Standby Mode

(Arming is not enable)

Enable

Arming Status

Alarm Trigger

Green Led Flash Quickly

Red Led Flash Quickly

Green Led Flash

Arming Delay TM

Enable Arming

Standby Mode

(Arming is not enable)

Alarm Relay TM

Alarm Delay TM

Alarm trigger