SOYAL
ACCESS CONTROL SYSTEM
®
AR-723 (H)
V220624
- 3 -
Enter the program mode
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input
876112
→
program mode accessed
Exit the program mode
Input
Operation process
M4/M8: Individual pass code
Card or PIN:
Access programming mode
→
12 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 ]
Card and PIN:
Access programming mode
→
13 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 13 00001 1234 ]
M6: Public pass word
Card or PIN:
Access programming mode
→
15 PPPP [Input 4-digit pass code, default value: 4321]
Card and PIN:
Access programming mode
→
17 PPPP [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]
B. Set up the password
[Only for connect to external K-series reader]
Master Code modification
Access programming mode
→
09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] Set the Master code to be 876112, input
123456
→
09 876112876112
A. Enter/ Exit Program Mode
C. Lift control
Enable
Access programming mode
→
24 002 [002= enable lift control]
Connect with
AR-401RO16B
to control floors which the user will be able to access.
[e.g.] User address NO. 168, only to the 6th and the 20th floor:
Access programming mode
→
21 00168 0 00100000
→
21 00168 2 00001000
Multi floors
Access programming mode
→
21 UUUUU S FFFFFFFF
[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable)
Single floor
[e.g.] User address NO. 45, allow to access the 24th floor:
27 00045 24
Access programming mode
→
27 UUUUU FF
UUUU=User Address FF=Floor number (01~32 floor)
Set
Floor/ Stop
F
8
16
24
32
0
1
2
3
F
6
14
22
30
F
7
15
23
31
F
5
13
21
29
F
4
12
20
28
F
3
11
19
27
F
2
10
18
26
F
1
9
17
25
D. Setting Up the Arming
[Only for connect to external K-series reader]
Mode4 / Mode6 / Mode8
※
Mode 6,
the number of users up to 65535, since it reads
CARD CODE
(5 digits) only, unlike that Mode4/Mode8 read
SITE CODE
and
CARD CODE
(10 digits).
If Access Mode setting to use the PIN,
it
need to external the K-series Readers.
Mode Networking/
Stand-Alone
User
Capacity
Access Mode
Auto-show
Duty time
Event log
Capacity
120
Holidays
Anti
force
Time
Zone
Lift
Control
Anti-pass-
back
M4
Networking/
Stand-Alone
1,024
1.Card only
2.Card and PIN
(4-digit PIN)
+
3.Card or User address
(5-digit)
+ Individual PIN
(4-digit
individual PIN)
+
Yes
1,200
Yes
Yes
No
32
Yes
M6 Stand-Alone
65,535
1.Card only
2.Card and PIN
(4-digit public PIN= Arming PWD)
+
3.Card or PIN
(4-digit public PIN= Duress code)
No
No
No
No
No
No
No
M8
Networking/
Stand-Alone
1,024
1.Card only
2.Card and PIN
(4-digit individual PIN)
+
3.Card or PIN
(4-digit individual PIN)
Yes
1,200
Yes
Yes
No
32
Yes
※
M6:
the user capacity can be 65535 because it only reads 5-digits
CARD CODE
, while in
M4/M8
it reads both
SITE CODE
and
CARD CODE
(10 digits).
In the security management of access control system, the controller or reader status is divided into Standby Mode or Disarming Mode and Arming
Mode. The conditions for triggering the alarm in these two modes is different, as shown in the following comparison:
Alarm conditions:
1. Door is forced open
Application:
1. Door open too long
: Door is open longer than door relay time plus door close time.
2. Force open
(Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal
: Arming is enabled and the power is suddenly off then on.