background image

V110412

   

WG 1
WG 0

BZ

GLED
RLED

12V

GND

1
2
3
4
5
6
7
8

1
2
3
4
5

WG 1
WG 0
BZ
GLED
RLED

GND

12V

12V

GND

P2

P1

B-

A+

B-

A+

B-

A+

Host

CH1

CH2

1
2

1
2

1
2

1
2

1
2

GND

12V

A+

B-

B-

A+

B-

A+

B-

A+

B-

A+

B-

A+

P3

P3

P3

P3

P3

Node 1

Node 9

Node 8

Node 16

EXIT

1
2
3
4
5
6
7
8

1   2   3

N.C.
N.O.

COM

CTL
12V

GND

PB

12V

GND

12V
GND

12V

GND

ARM

P1

P5

AR-721RB

N.C.
N.O.

COM

CTL

12V

1
2
3
4
5
6
7
8

Door Contact

ALM

12V

GND

12V

GND

12V

GND

N.C.

12V

GND

P1

EXIT

1
2
3
4
5
6
7
8

N.C.

COM

PB

12V

GND

12V

GND

12V
GND

12V

GND

N.O.

P1

EXIT

1
2
3
4
5
6
7
8

12V

GND

12V
GND

12V

GND

N.O.

N.O.

COM

PB

12V

GND

P1

N.O.

12V

GND

EXIT

N.C.
N.O.

COM

CTL

12V

10

9
8
7
6
5
4
3
2
1

AR-331H

P7

N.O.

12V

GND

Lock

PB

12V

GND

N.C.
N.O.

COM

CTL

12V

10

9
8
7
6
5
4
3
2
1

N.C.

N.O.

COM

CTL

12V

P7

N.C.

Door

Contact

ALM

COM

N.O.

12V

GND

AR-331H

Access Controller

Touch-panel Metal Housing / Illuminated Touch-panel

Strengthen security with AR-721RB

Connect to Access Control for

Connect to arming tools for

Connect to Reader

Alarm

Alarm

Tamper Alarm

Controller 

Reader

Controller 

Controller 

AR-716E

Controller 

Controller 

Controller 

Controller 

Controller 

Converter

Node ID 001

Node ID 254

Door Contact

Door Contact

Relay Outpot Module 

Relay Outpot Module 

Alarm Relay

Tamper Relay

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

Connect to Door Sensor

Connect to Networking

Request To Exit

Request To Exit

Electric Bolt

Electric Bolt

※ 

1.Enable the security trigger signal: Please refer to the 34      DDD

     2.Disable the door open button input. (Please refer to the 

        20      DDD      of function default value.)

Connect to Magnet Lock or Electric Bolt

Electric Bolt

or

Magnet Lock

Controller 

Request To Exit

POWER

12VDC

POWER

12VDC

Connect to Electric Strike

Wiring Diagram

Electric Strike

Controller 

Request To Exit

POWER

12VDC

POWER

12VDC

If use the AR-721RB, 

please refer to the top of 

the wiring diagram.

P7

P7

Summary of Contents for AR-321H

Page 1: ...725X 1 Product 1 Product 1 Product 1 Product 1 Products 1 Products 1 Products 3 User Guide 2 Optional 2 User Guide 2 User Guide 2 User Guide 2 User Guide 2 User Guide 4 Terminal Cables 3 Terminal Cab...

Page 2: ...the metal casing back and lock it with security screw Finally put the Protection plug into the hole Turn on the power and LED will light and beep will sound Pull the cables from the square hole of th...

Page 3: ...White Green White Description BE Output AR Output Security trigger signal Output DU Output TTL out Hi input Green light brighten P6 Cable AR 321H AR 721H AR 331H AR 725H AR 757H Wire Application Lock...

Page 4: ...nel Strengthen security with AR 721RB Connect to Access Control for Connect to arming tools for Connect to Reader Alarm Alarm Tamper Alarm Controller Reader Controller Controller AR 716E Controller Co...

Page 5: ...sequential tags 62312 62332 Access programming mode 19 00101 00120 Close Tag into RF Area only use the tag NO 62312 OK Tag Information SITE CODE CARD CODE SITE CODE CARD CODE Mode6 At this mode User...

Page 6: ...User address 00001 and pass code 1234 input 13 00001 1234 M6 Public pass word Card or PIN Access programming mode 15 PPPP Input 4 digit pass code default value 4321 Card and PIN Access programming mod...

Page 7: ...thout cards at auto open zone Alarm Output Lift Control Stop Alarm by door close or by push button Door bell 0 Disable 0 Alarm Output 0 None 0 Disable Networking Stand Alone Networking Stand Alone Net...

Page 8: ...ay time 001 600 1 600 sec SSSSS EEEEE 00000 01023 00000 03000 for AR 725H SSSSS Starting user address EEEEE Ending user address N 0 1st time zone 1 2nd time zone HHMM Starting time hhmm ending time i...

Reviews: