Soyal AR-0600M Quick Start Manual Download Page 6

V200724

ACCESS & INDUSTRIAL CONTROL

SOYAL

    

1

1

1

1

2

3

2

2

2

2

3

- 4 -

SOYAL

SOYA

L

SOYA

L

AR-0600M Electromagnetic Lock

 

Installation Instruction

4

7

1

6

8

2

5

3

Remove the Mounting Plate 

from the lock body

Install lock body on the Mounting Plate 

Draw positioning line of lock 

body

Wiring & Voltage Adjustment

Complete the assemble of The Mounting Plate

on the Lock body

Mark hole drilling position

Mounting Plate fix to door 

frame 

Hole drilling

Stick the Installation Template sticker into 

the hole drilling position and mark the 

hole drilling position for lock body 

Drill the hole based on the hole position 

on the sticker, after it is done, remove the 

sticker

Put the lock body into the door frame, compare 

it to the armature plate position (the position 

should be considering armature plate position, 

so when door is closed, lock is properly locked).

Draw the lock body position for marking.

Step 1: 

Patented Anti-Falling Design, with flat shrapnel on both sides of 

the magnetic lock, starting from left or right, tilt the lock to either left or 

right and buckle the flat shrapnel

Step 2: 

Continue to buckle the other side, so that the magnetic lock 

body and the Mounting Plate are tightly buckled

Use the Hexagon Allen Wrench to fix the magnetic lock on 

the Mounting Plate.

Step 1:

 Use provided Hexagon Allen Wrench to 

loosen the screws on the lock body to the state 

where the Mounting Plate can be removed (do not 

remove all)

Step 2: 

Move the Mounting Plate to the left or right 

by approx.1mm

Step 3:

 Remove the flat shrapnel from the Mounting 

Plate and pull upward

Step 1:

 Loose the screw to open Cover 

Part

Step 2: 

Wire cable and bring the cable 

out to the hole and adjust voltage if 

necessary

Step 3:

 Fix the Cover Part back with the 

screw

Step 1: 

Fix the middle hole on the door frame 

position with Fixing Screw 4mm*25mm.

At this time, you can adjust the installation 

position.

Step 2:

 Fix the remaining holes with Fixing 

Screw 4mm*25mm to the door frame to finish 

Mounting Plate installation.

Summary of Contents for AR-0600M

Page 1: ...nti residual magnetism part located the edge of electromagnet more durable than conventional anti residual magnetism design that easily oxidized dust on the armature plat Patent no Taiwan M597321 EP 2...

Page 2: ...Output With time delay EXIT N O COM N C V V COM N C N O CTL 12V PB GND Power DC12V 24V Relay AR 721RB Push Butt on Magnetic Lock 1 2 3 4 5 6 7 8 COM N C SENSOR 12V GND N O COM N C V V Controller Magn...

Page 3: ...per position of the door and frame Mark the hole positions and drill the hole For Armature Plate Installation Diagram Template for armature plate is divided into Part 1 Standard Installation holes pos...

Page 4: ...armature plate s part and place it into the door position Drill the hole based on the hole position on the sticker after it is done remove the sticker Armature Installation Side View 1 2 5 3 6 Separa...

Page 5: ...e plate s part and place it into the door position Drill the hole based on the hole position on the sticker after it is done remove the sticker Armature Plate Installation Reference 1 4 2 5 3 6 Instal...

Page 6: ...1 Patented Anti Falling Design with flat shrapnel on both sides of the magnetic lock starting from left or right tilt the lock to either left or right and buckle the flat shrapnel Step 2 Continue to b...

Page 7: ...6190 AR 0600MZL L Lock AR 0600M Bracket AR MA 46190 AR 0600MU Door Frame Door Frame Installation with Bracket U Bracket Electromagnetic Lock Electromagnetic Lock Electromagnetic Lock Electromagnetic L...