Installation Procedure continued
9. Find the nearest 12 VDC power source. The power source must be from a circuit protected by a 20 Amp circuit breaker. Using power
from a compartment is not recommended as these normally do not have a high enough amperage rating.
10. Route the wiring to the desired position of the switch previously located.
11. If using Southwire supplied switch assembly MH2021, refer to wiring diagram (Figure A). If using an alternate switch not supplied by
Southwire refer to wiring diagram (Figure B). Alternate switch must be a DPDT, (ON) OFF (ON) rocker type capable of handling 20
Amps VDC. All wiring regardless of switch used must be 14 AWG with all applicable terminals sized appropriately.
12. Reconnect the 12 VDC power supply.
13. Connect the input side of the hose reel to the water output port using adapter hose available from Southwire or equivalent hose rated
for potable water. If connection is made to a portable water system, the system shall be protected against backflow. Use applicable
thread sealer on hose end threads to prevent leaking.
14. Feed the hose from the hose reel through the porthole or access door. Refer to OPERATING INSTRUCTIONS for more information.
15. Test the unit by following steps listed in OPERATING INSTRUCTIONS
MODEL #RW