SET UP AND OPERATION

USING WITH SOUTHWIRE™ TRIGGERS

® 

TROUBLESHOOTING

SPECIFICATIONS

•    Model# MFC-01
•    Stock # 58-13-33-01
•    Length- 44 Inches
•    Width- 26 Inches
•    Height- 35 Inches
•    Min. Cable Size- 3/0
•    Max Cable Size- 3-1/2 Inches
•    Max Feet Per Minute- 30 fpm
•    Tension Force- 1600 pound with multiple 
      conductors: 400 pounds on a single conductor
•    Patent- CA2735611A1, US8408520, US20130248785

MAINTENANCE

•  T-Handle must be braced against cable reel or an immovable 
    object usually with a piece of strut or wood. To extend Feeder 
    distance from the reel unscrew T-Handle at the coupling and 
    screw on a 1” rigid pipe or insert a 1-1/2” piece of EMT or larger
    through the handle and brace it against the strut or wood beam. 
    (Fig. 7)
•  When adding a ground cable to the feeder place it with the rest 
    of the cable and it will pull through with the other cables. Place 
    the ground reel on a jack with encased bearings such as the 
    Maxis

®

 Jax for easier payoff.

•  When using the Maxis

®

 Triggers

®

 make sure that the “Trigger 

    Option” button is engaged.
•  When not using the Maxis

®

 Triggers

®

 make sure that the 

    “Trigger

®

 Option” button is not engaged.

•  For faster or slower speeds engage the High/Low switch (12).
•  If the Maxis

®

 Feeder displays no power, check for a blown fuse

    in the bottom of the Control Panel. Replace with a 20 amp, 
    120V round fuse.

The Maxis

®

 Feeder can be used in stand alone or in tandem with a 

cable puller all controlled by the Southwire Triggers

®

. The South-

wire Triggers

®

 is a wireless safety switch system that allows both 

the person operating the puller and the person operating the 
feeder, control over the puller and feeder operation. Both 
footswitches must be engaged for the puller’s motor and feeder to 
operate. Anytime either footswitch is released the puller’s motor 
and the Feeder will disengage. Refer to the Southwire Trigger’s 
owner’s manual for specific instructions regarding Trigger use.
1. Plug the RCA Cord (9) from the Maxis

®

 Feeder into the Triggers 

    Adaptor box (Fig 5) and plug adaptor box into the back of the 
    Trigger Remote pedal.
2. Plug Feeder Power cord into extension cord from power source.
3. Plug Triggers remote foot switch into extension cord from 
    power source.
4. Follow Triggers Instruction manual for Triggers setup.
5. Push on small green “Trigger Option” button on the Feeder 
    control panel (7) (Fig 6).
6. Push forward green button on Control Panel.
7. Feeder will only power on when Trigger pedals are engaged.
8. Adjust speed with Speed Control dial.
9. To STOP, lift foot off Trigger pedal.
10. STOP motor before opening lid.

•    As needed check and oil tension chain.

Summary of Contents for MAXIS MCF-01

Page 1: ...OPERATING and MAINTENANCE INSTRUCTIONS MAXIS Feeder MCF 01 READ AND UNDERSTAND ALL OF THE INSTRUCTIONS AND SAFETY INFORMATION IN THIS MANUAL BEFORE OPERATING OR SERVICING THIS TOOL 04 17 MCF 01 Manual...

Page 2: ...arkings on the tool provide information for avoiding hazards and unsafe practices related to the use of this tool Observe all of the safety information provided SAFETY ALERT SYMBOLS These symbols are...

Page 3: ...s immediately Damaged cords can increase the risk of electric shock Do not use this tool near live circuits Shut off and lock out power when working near existing circuits FAILURE TO OBSERVE THESE WAR...

Page 4: ...lube cable Pushes wire at up to 1 600 lbs of force and speeds up to 30 fpm Completely adjustable tension lid can be controlled without s topping the pull Feeds cable from sizes 3 0 up to 3 5 in diame...

Page 5: ...nly onto rollers Fig 3 7 Shut Tension Lid by lifting the Lid Safety Latch then lowering lid 6 8 Push Tension Lid down onto cable and latch Tension Lid Locking Pin 19 9 Tension may need to be decreased...

Page 6: ...eeder displays no power check for a blown fuse in the bottom of the Control Panel Replace with a 20 amp 120V round fuse The Maxis Feeder can be used in stand alone or in tandem with a cable puller all...

Page 7: ...tuds grips will be free from manufacturer defects for a period of one year from the date of the original end user s purchase Under this 1 Year Limited Warranty Southwire Company LLC will have no liabi...

Reviews: