background image

8. Wiring portion is now complete, so you can install bulbs. Again, double check wall 

switch is in off position and power is shut off at breaker. 

 

OPERATION

 

 

SET-UP AND ADJUSTMENT

 

Follow these steps to set up your security light for best operation.   
1. Turn power switch on and wait 60 seconds for the system’s circuitry to stabilize.   

2. Turn the “Time” knob to the fully counter clockwise direction.   

3. Turn the “Range” control all the way in a counter clockwise direction.   

4. Aim the control module to the desired target area. Have a person stand 

approximately in the center of the target area moving slightly. Moving arms up and 

down is usually sufficient.   

5. Slowly rotate the “Range” knob clockwise until the lights go on. You may adjust the 

“Range” control either way to the desired sensitivity level.   

6. Turn the 

TIME

 knob clockwise to adjust how long you want the lights to stay on after 

the unit is activated. The maximum (full clockwise) is about 10 minutes. The minimum 

(full counter clockwise) is about 30 seconds.   

Test Mode

Activate the photocell and allow the motion detector to
function in daylight for time setting.

Auto Mode

Turn knob from 30 seconds to 10 minutes as needed.

Manual Override

Mode

Turn the wall switch

 Off-On twice within 2 seconds

, the

lights will come on and stay on. After 6 hours, this option
will automatically return to Auto Mode.

Manual Override to

return to Auto Mode

During the light-on period in manual override mode, turn
the wall switch 

Off-On once within 1 second

, this option

will reset sensor to Auto Mode.

Temperary On Mode

Turn the wall switch 

Off-On once within 1 second

, the

lights will come on to support users' immediate need(light
on based on "Time" setting). Time will be reset to extend
the lights on.

Temperary On to

return to Auto Mode

During the light-on period in temperary on mode, turn the
wall switch 

Off-On three times within 3 seconds

, this

option will reset sensor to Auto Mode.

LED Indicator

1.During the warm-up time, LED is on until warm-up finish.
2.During Test Mode, LED is the indicator to show user in
the detection zone. When the sensor is triggered, the light
is on, and LED starts flash. When user is out of detection
zone, LED stops flash.
3.LED is always flash slowly to warn the intruder.

Summary of Contents for L6003

Page 1: ...is warranted to be free of defects in workmanship and materials for a period of 1 year from the original date of purchase If any problems appear other than burnt out bulbs which carry no warranty wit...

Page 2: ...handled through Southwire Co HOW IT WORKS Congratulations on the purchase of your Southwire Co motion sensor light with infrared detection The motion detector turns lights on and off after sensing mo...

Page 3: ...sources of light Keep in mind areas with traffic pets or other moving objects may cause nuisance triggering 3 Do not aim at highly reflective surfaces such as smooth white walls waterfalls or windows...

Page 4: ...ing to mount fixture 5 Slide the black foam gasket over the white black and green wires It seals the base to the wall when installed helping keep moisture out 6 See diagram above A Using wirenuts conn...

Page 5: ...tivate the photocell and allow the motion detector to function in daylight for time setting Auto Mode Turn knob from 30 seconds to 10 minutes as needed Manual Override Mode Turn the wall switch Off On...

Page 6: ...detector wire C Ground wires 3 Check to make sure each lamp is minimum 40 watts and total does not exceed total 500 Watts Motion Detector triggers on with motion and stays on 1 Move floodlights away...

Page 7: ...ds pools of water windows or smooth walls 4 Adjust Range sensitivity setting 5 Make sure motion detector is mounted on firm surface as mechanical vibrations can cause false triggering NOTE Occasionall...

Reviews: