6

1. Turn off power to the circuit before testing. 
2. Touch the test probes to the wire or device being tested.  
3. The 

CONTINUITY “•)))”

 LED will illuminate and the

    beeper will sound if the resistance is from 0 to <300k

Ω

Operation cont.

Continuity Test

1. Connect Test Probe L1 to the supposed phase L1 and Test Probe L2

    to the supposed phase L2. 
2. 

R)

 signifies the supposed L1 is the actual phase L1 and the supposed L2

    is the actual phase L2. 

(L  

signifies that the supposed L1 is the actual

    phase L2 and the supposed L2 is the actual phase L1.
3. To verify results, reverse connections. The opposite indicator must

    illuminate to validate test. 

NOTE:

 The 

(L 

or

 R)

 rotary field indicator will illuminate

when measuring single phase AC voltage. However,

the indication is only valid when testing a three phase circuit. 

Rotary Field Indication

Press and hold the      button to turn on the flashlight.

Releasing the button will turn the flashlight off. 

Flashlight

Wire

 

               

Observe all safety precautions when

working on live voltages.

WARNING:

 

5

Operation cont.

AC/DC Voltage Measurements cont. 

Indicators/Warnings

12VDC

Indicators/Warnings

12VDC

 

               

Observe all safety precautions when

working on live voltages.

WARNING:

 

1. Touch the (

L2

) test probe to the device or circuit being

    tested. (Does not detect through insulation.)
2. The “    ” live AC voltage indicator will illuminate

    when detecting AC voltage from 100 to 480V.

    No actual voltage indication will be shown. 

NOTE:

 The single-pole test can fail to detect a live voltage

under certain conditions. Use another method to check

for voltage before performing work on live equipment.

(Refer to AC/DC Voltage Measurements in manual)

Single Pole Voltage Test

Summary of Contents for 41170S

Page 1: ...reserved southwiretools com 1 855 SW T00LS Toll Free Technical Help L nea de Ayuda T cnica Gratuita Scan for warranty information and to access our mobile site Escanea para informaci nde garant a y ac...

Page 2: ...t exceeds the tester s maximum rated input limits 2 Input Limits Function Maximum Input Voltage DC Voltage AC Continuity Single Pole Voltage Detection Rotary Field Indication 600V 600V 600V 600V Inter...

Page 3: ...witch AUTO TEST 11 Flashlight on button 12 Battery case 13 LED for DC polarity 14 LED for DC polarity NOTE 13 LED and 14 LED illuminate for AC voltage indication 1 2 3 Indicators Warnings 4 5 6 7 8 9...

Page 4: ...ver the indication is only valid when testing a three phase circuit Rotary Field Indication Press and hold the button to turn on the flashlight Releasing the button will turn the flashlight off Flashl...

Page 5: ...quick and easy LIMITED WARRANTY AND LIMITATION OF LIABILITY ON SOUTHWIRE METERS TESTERS Southwire Company LLC warrants this product to be free from defects in material and workmanship for two years f...

Page 6: ...edor de polvo vapor o gases explosivos No use el probador si no est funcionando correctamente La protecci n puede estar comprometida No aplique un voltaje o corriente que exceda el l mite de entrada m...

Page 7: ...inuidad 10 Interruptor para Auto Prueba 11 Bot n para encender linterna 12 Estuche de bater as 13 LED para polaridad DC 14 LED para polaridad DC NOTA LED 13 y LED 14 se iluminan para indicar voltaje A...

Page 8: ...va a comprobar 3 El LED de continuidad se iluminar y el b per sonar si la resistencia est entre 0 a 300k Prueba de Continuidad 1 Conecte la sonda de prueba L1 a la supuesta fase L1 y la sonda de prue...

Page 9: ...es y mano de obra por dos a os desde de la fecha de compra Esta garant a no cubre fusibles bater as desechables ni da os como resultado de un accidente negligencia mala aplicaci n contaminaci n modifi...

Reviews: